In Vivo Real-Time Detection of Phenylephrine in Mice Using Boron-Doped Diamond Microelectrodes with Simultaneous Video-Based Assessment of Pupil Size
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c02398 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Chuxing Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama223-8522, Japan. Hauptthemen laut MEDLINE: Phenylephrine, Diamond, Boron, Electrochemical Techniques. Die Arbeit nennt 36 Literaturangaben. Gefördert von: Takeda Science Foundation, Japan Society for the Promotion of Science, Japan Science and Technology Agency.
Abstract (Originalsprache)
Precise quantification of ocular pharmacokinetics remains a critical bottleneck in ophthalmic drug development, primarily constrained by the inability to monitor intraocular concentrations in real time. Current methods typically rely on destructive sampling, which precludes longitudinal assessment in individual subjects. Here, we report an electrochemical platform for time-resolved quantification of phenylephrine in the anterior chamber of living mice using needle-shaped boron-doped diamond microelectrodes. An optimized multistep potential protocol mitigated biofouling and enabled stable monitoring of intraocular drug dynamics while simultaneously assessing pupillary response via video. Across a range of topical doses, intraocular exposure increased with applied concentration, whereas pupil dilation showed a saturating dependence and clear pharmacokinetic–pharmacodynamic (PK/PD) hysteresis, consistent with a temporal lag between local drug availability and physiological response. This platform enables time-resolved in vivo PK/PD analysis and provides a practical framework for evaluating and optimizing ocular drug delivery strategies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Faculty of Science and Technology, Keio University, 3-14-1 Hiyoshi, Yokohama223-8522, Japan.
- Department of Ophthalmology, School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo113-8655, Japan.
ORCID-Profile: Genki Ogata, Yasuaki Einaga
Förderung
- Takeda Science Foundation
- Japan Society for the Promotion of Science
- Japan Science and Technology Agency
Zitieren
APA
Liu, C., Ogata, G., Zhang, Z., Yamagishi, R., Honjo, M., Aihara, M., & Einaga, Y. (2026). In Vivo Real-Time Detection of Phenylephrine in Mice Using Boron-Doped Diamond Microelectrodes with Simultaneous Video-Based Assessment of Pupil Size. ACS Sensors. https://doi.org/10.1021/acssensors.6c02398
Vancouver
Liu C, Ogata G, Zhang Z, Yamagishi R, Honjo M, Aihara M, et al. In Vivo Real-Time Detection of Phenylephrine in Mice Using Boron-Doped Diamond Microelectrodes with Simultaneous Video-Based Assessment of Pupil Size. ACS Sensors. 2026. doi:10.1021/acssensors.6c02398