DNA Lever Nanomachine Based on CHA-Driven Conformational Transitions for the Detection of ctDNA
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c02322 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Si Ying Wu und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, PR China. Hauptthemen laut MEDLINE: Biosensing Techniques, Circulating Tumor DNA, DNA, Nanotechnology. Die Arbeit nennt 42 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Chongqing Municipality.
Abstract (Originalsprache)
Cancer incidence is high worldwide, and early treatment can reduce mortality rates. Circulating tumor DNA (ctDNA) serves as a biomarker for liquid biopsy, enabling early monitoring of tumor burden and treatment response. DNA nanobiosensors have become an important tool for detecting ctDNA due to their high efficiency and low cost. In this study, we developed a DNA lever nanomachine (DLN) based on a catalytic hairpin assembly (CHA)-driven conformational transition for the sensitive detection of ctDNA. The principle is to combine the CHA reaction with DNA lever-based mechanical amplification, enabling the detection of target ctDNA by monitoring changes in signal intensity. During the initial preparation stage, the nanomachine remains in a fluorescence-quenched state. When target ctDNA is present, CHA is activated, triggering downstream signal transduction and initiating a synergistic process of “target capture-conformational transition-signal amplification”, ultimately leading to the restoration and amplification of the fluorescence signal. Additionally, by adjusting the fulcrum position, this machine enhances mechanical efficiency through an effort-saving lever mechanism. It minimizes internal driving force requirements by optimizing the torque load value at the load end, thereby further improving system responsiveness. The established fluorescent biosensing platform achieves satisfactory linear correlation with ctDNA concentrations ranging from 1 pM to 100 nM, with a limit of detection of 0.776 pM. This method offers a new strategy for CHA-based DNA mechanical fluorescence sensing and holds significant application potential in biological sample detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, Southwest University, Chongqing400715, PR China.
- School of Chemistry and Materials, Nanning Normal University, Nanning530001, People's Republic of China.
ORCID-Profile: Nian Bing Li, Hong Qun Luo
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Chongqing Municipality
Zitieren
APA
Wu, S. Y., Fu, Q. T., Lei, Y. Y., Wang, Y. N., Tang, Y., Wang, Z., Zhu, R., Xiao, Q., Li, N. B., & Luo, H. Q. (2026). DNA Lever Nanomachine Based on CHA-Driven Conformational Transitions for the Detection of ctDNA. ACS Sensors. https://doi.org/10.1021/acssensors.6c02322
Vancouver
Wu SY, Fu QT, Lei YY, Wang YN, Tang Y, Wang Z, et al. DNA Lever Nanomachine Based on CHA-Driven Conformational Transitions for the Detection of ctDNA. ACS Sensors. 2026. doi:10.1021/acssensors.6c02322
BibTeX
@article{Wu2026,
author = {Wu, Si Ying and Fu, Qi Tong and Lei, Ya Yun and Wang, Yi Nuo and Tang, Yuan and Wang, Zhen and Zhu, Rui and Xiao, Qi and Li, Nian Bing and Luo, Hong Qun},
title = {DNA Lever Nanomachine Based on CHA-Driven Conformational Transitions for the Detection of ctDNA},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c02322}
}
EUVIMED