Fluidic Lipid-Bilayer-Enhanced Iontronic Nanopore: Machine-Learning-Driven Ultrasensitive MicroRNA Detection in Cancer Diagnostics
ACS Sensors · 24.07.2026 · 11 (7) · 6446-6456
DOI: 10.1021/acssensors.6c02053 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 06.07.2026. Verfasst von Yanlei Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Ji…. Hauptthemen laut MEDLINE: MicroRNAs, Nanopores, Lipid Bilayers, Machine Learning. Die Arbeit nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shandong Province, Taishan Scholar Project of Shandong Province.
Abstract (Originalsprache)
Ultrasensitive detection of microRNA (miRNA) is critical for precision diagnostics. However, conventional surface-based DNA walkers are intrinsically limited by slow kinetics arising from the static nature of solid-state substrates. Here, we report a dynamic DNA walker operating on a fluidic supported lipid bilayer (SLB) integrated with an anodic aluminum oxide (AAO) nanopore. Fluorescence recovery after photobleaching (FRAP) confirms the lateral mobility of lipid-anchored probes with a diffusion coefficient D ≈ 1.2 μm2/s. This fluidity enables the active replenishment of local reactants. This fundamentally shifts the system from a diffusion-controlled to a reaction-controlled regime (Damköhler number, Da <1), allowing the walker to operate at its intrinsic catalytic efficiency and reach equilibrium in 30 min. Signal transduction is governed by a synergistic regulation of the effective pore diameter (deff) and surface charge density (σ), triggering a hydrophobicity-modulated conductance switch. This platform achieves a limit of detection of 25 aM for microRNA-21 (miR-21) and enables clinical sample classification with >98% accuracy using an interpretable decision-stump model, confirming that the dominant diagnostic information is captured by a single high signal-to-noise current feature. This work establishes substrate fluidity as a core design principle for next-generation iontronic sensors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan250022, P. R. China.
- School of Chemistry and Chemical Engineering, Southeast University, Nanjing211189, P. R. China.
- Department of Chemistry, Sungkyunkwan University, Suwon16419, Republic of Korea.
ORCID-Profile: Xiang Ren, Dan Wu, Hongmin Ma, Zhongfeng Gao, Qin Wei
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
- Taishan Scholar Project of Shandong Province
Zitieren
APA
Li, Y., Zhang, S., Ren, X., Wu, D., Ma, H., Gao, Z., & Wei, Q. (2026). Fluidic Lipid-Bilayer-Enhanced Iontronic Nanopore: Machine-Learning-Driven Ultrasensitive MicroRNA Detection in Cancer Diagnostics. ACS Sensors, 11(7), 6446-6456. https://doi.org/10.1021/acssensors.6c02053
Vancouver
Li Y, Zhang S, Ren X, Wu D, Ma H, Gao Z, et al. Fluidic Lipid-Bilayer-Enhanced Iontronic Nanopore: Machine-Learning-Driven Ultrasensitive MicroRNA Detection in Cancer Diagnostics. ACS Sensors. 2026;11(7):6446-6456. doi:10.1021/acssensors.6c02053
BibTeX
@article{Li2026,
author = {Li, Yanlei and Zhang, Saimei and Ren, Xiang and Wu, Dan and Ma, Hongmin and Gao, Zhongfeng and Wei, Qin},
title = {Fluidic Lipid-Bilayer-Enhanced Iontronic Nanopore: Machine-Learning-Driven Ultrasensitive MicroRNA Detection in Cancer Diagnostics},
journal = {ACS Sensors},
year = {2026},
volume = {11},
number = {7},
pages = {6446--6456},
doi = {10.1021/acssensors.6c02053}
}
EUVIMED