Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Sherman Lesly Zambou Jiokeng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081Ulm, Germany. Hauptthemen laut MEDLINE: Diclofenac, Solid Phase Extraction, Molecularly Imprinted Polymers, Water Pollutants, Chemical. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Horizon 2020 Framework Programme, Universität Ulm.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of pharmaceutical micropollutants in wastewater remains challenging due to complex matrices and low target concentrations, limiting timely detection of emerging contaminants. We report a field-deployable wastewater spectroscopic analyzer (WSA) that combines mid-infrared quantum cascade laser spectroscopy (QCL) absorption spectroscopy with selective sample preconcentration to quantitatively identify diclofenac (DCF), a widely used anti-inflammatory drug and recognized EU priority pollutant, in wastewater. Raw samples are first filtered to remove particulates, then selectively concentrated using a diclofenac-molecularly imprinted polymer-based solid phase extraction (MIP-SPE), and finally eluted as a methanol solution into a mid-infrared flow cell for spectral quantification. This integrated workflow enables autonomous operation with minimal manual intervention, addressing a key limitation of conventional laboratory-based analysis. The technique was validated against reference chromatography/mass spectrometry methods during filed deployment at a hospital and a municipal wastewater treatment plant, showing strong agreement (91–92%) and confirming its potential as a practical tool for autonomous, real-time pharmaceutical surveillance and early-warning monitoring in wastewater.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DiclofenacSolid Phase ExtractionMolecularly Imprinted PolymersWater Pollutants, ChemicalMolecular ImprintingLasers, SemiconductorPolymersAnti-Inflammatory Agents, Non-SteroidalWastewater

Stichwörter der Autor:innen

diclofenacfield-deployable sensormid-infrared spectroscopicmolecularly imprinted polymerquantum cascade lasersolid-phase extractionwastewater monitoring

Substanzen

DiclofenacWastewaterMolecularly Imprinted PolymersWater Pollutants, ChemicalPolymersAnti-Inflammatory Agents, Non-Steroidal

Autor:innen und Institutionen

  • Institute of Analytical and Bioanalytical Chemistry, Ulm University, Albert-Einstein-Allee 11, 89081Ulm, Germany.
  • CY.R.I.C Cyprus Research and Innovation Center Ltd , 2643Nicosia, Cyprus.
  • Athens Water Supply and Sewerage Company S.A (EYDAP), Research and Development , 156 Oropou Str., 11146Athens, Greece.
  • Alpes Lasers SA , 2072St. Blaise, Switzerland.
  • MHTERA Hospital , 6, Erythrou Stavrou Str., Marousi, 15123Athens, Greece.

ORCID-Profile: Sherman Lesly Zambou Jiokeng, Giorgos Katsouras, Boris Mizaikoff

Förderung

  • Horizon 2020 Framework Programme
  • Universität Ulm

Zitieren

APA

Zambou Jiokeng, S. L., Adamou, D., Huber, A., Debard, L., Katsouras, G., Georgiadis, P., Vasileiadis, M., Yfanti, A., Zacharouli, Z., Margaritis, P., & Mizaikoff, B. (2026). Mid-Infrared Quantum Cascade Laser Sensor System with Molecularly Imprinted Polymer Solid Phase Enrichment for Diclofenac Monitoring. ACS Sensors. https://doi.org/10.1021/acssensors.6c01927

Vancouver

Zambou Jiokeng SL, Adamou D, Huber A, Debard L, Katsouras G, Georgiadis P, et al. Mid-Infrared Quantum Cascade Laser Sensor System with Molecularly Imprinted Polymer Solid Phase Enrichment for Diclofenac Monitoring. ACS Sensors. 2026. doi:10.1021/acssensors.6c01927

BibTeX
@article{ZambouJiokeng2026,
  author = {Zambou Jiokeng, Sherman Lesly and Adamou, Dionysis and Huber, Amelie and Debard, Lauralie and Katsouras, Giorgos and Georgiadis, Panagiotis and Vasileiadis, Miltiadis and Yfanti, Anthi and Zacharouli, Zoe and Margaritis, Panagiotis and Mizaikoff, Boris},
  title = {Mid-Infrared Quantum Cascade Laser Sensor System with Molecularly Imprinted Polymer Solid Phase Enrichment for Diclofenac Monitoring},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c01927}
}
Kostenlos starten →