Ultra-Wide ppb-to-ppm Dynamic Range for Room-Temperature Hydrogen Sensing via Obliquely Deposited Pd on Silicon Microcone Arrays
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c01895 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Xianwu Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu610031, China. Hauptthemen laut MEDLINE: Palladium, Silicon, Hydrogen, Temperature. Die Arbeit nennt 57 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.
Abstract (Originalsprache)
Developing hydrogen (H2) sensors with ultralow detection limits, high response, and room-temperature operation is critical for the safe utilization of H2 energy. Herein, we report a highly sensitive H2 sensor based on palladium nanoparticle (Pd NP)-decorated silicon microcone (Si MC) arrays, with a systematic investigation of metal deposition conditions. Large-area, uniform, and smooth Si MC arrays were fabricated via metal-assisted chemical etching (MACE). The Pd deposition angle (0−90°) plays a vital role in sensing performance. The optimized 3 Pd-75° sensor (3 nm Pd, 75° deposition) exhibits an exceptional response of 2148.9% toward 10,000 ppm H2 at room temperature, along with fast recovery (∼4 s), good humidity tolerance, long-term stability, and excellent selectivity. Notably, it achieves an ultrawide quantitative detection range from 10 ppb to 2000 ppm. Furthermore, Pt modification reveals a trade-off between catalytic activity and electrical response: while Pt accelerates H2 dissociation and diffusion, it reduces response magnitude due to active site blocking and enhanced conduction pathways. The superior sensing performance arises from the synergistic effects of Pd catalysis, Pd/Si interfacial charge modulation, and the high surface area of the Si MC architecture. This work provides a promising strategy for low-power, high-performance room-temperature H2 sensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu610031, China.
- Institute of Smart City and Intelligent Transportation, Southwest Jiaotong University, Chengdu611756, China.
- School of Mechanical Engineering, Southwest Jiaotong University, Chengdu610031, China.
ORCID-Profile: Hongbo Wang, Zhi-Jun Zhao, Bingjun Yu
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities
Zitieren
APA
Xu, X., Zhao, Y., Wu, Y., Wang, H., Lu, C., Qian, L., Zhao, Z. J., & Yu, B. (2026). Ultra-Wide ppb-to-ppm Dynamic Range for Room-Temperature Hydrogen Sensing via Obliquely Deposited Pd on Silicon Microcone Arrays. ACS Sensors. https://doi.org/10.1021/acssensors.6c01895
Vancouver
Xu X, Zhao Y, Wu Y, Wang H, Lu C, Qian L, et al. Ultra-Wide ppb-to-ppm Dynamic Range for Room-Temperature Hydrogen Sensing via Obliquely Deposited Pd on Silicon Microcone Arrays. ACS Sensors. 2026. doi:10.1021/acssensors.6c01895
BibTeX
@article{Xu2026,
author = {Xu, Xianwu and Zhao, Yuchao and Wu, Yichen and Wang, Hongbo and Lu, Caijiang and Qian, Linmao and Zhao, Zhi-Jun and Yu, Bingjun},
title = {Ultra-Wide ppb-to-ppm Dynamic Range for Room-Temperature Hydrogen Sensing via Obliquely Deposited Pd on Silicon Microcone Arrays},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c01895}
}
EUVIMED