EUVIMEDEUVIMED entdecken
Crossref

Response Transient-Aware Artificial Olfaction for Nitrogenous Biomarkers Recognition and Asthma Diagnosis

Liwen Mao, Zhenliang Dong, Tiange Gao, Jie Pan, Jiaxi Li, Xiaoyang Xiao, Jiaxin Yang, Yiling Liu, Qingmin Hu, Jiaqiang Xu iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c01518 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Liwen Mao und 9 weiteren Autor:innen. Beteiligte Einrichtung: NEST Lab, Department of Chemistry, College of Sciences, Shanghai University, Shanghai200444, China. Hauptthemen laut MEDLINE: Asthma, Nitric Oxide, Electronic Nose. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, China Postdoctoral Science Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Noninvasive disease diagnosis through the exhaled nitric oxide (NO) biomarker is of great significance for the real-time screening of asthma patients. Herein, a high-performance artificial olfactory system (E-nose) based on porous In2O3 nanorods functionalized with Pt, Pd, and PtPd was designed and prepared for the precise recognition of the asthma biomarker NO and the noninvasive diagnosis of asthma. The sensor array demonstrates a limit of detection (LOD) of approximately 1.33 ppb (PtPd/In2O3) for NO and maintains high selectivity. To overcome the prolonged response/recovery times of room-temperature gas sensors and the indistinguishable response values for structurally similar molecules, a novel response transient-aware prototypical network model is proposed. By dynamically extracting transient features from early response stages, the model achieves a high classification accuracy of 94.44% for structurally similar nitrogen oxides (NO, NO2, and N2O). On a clinical dataset comprising 61 participants (42 healthy volunteers and 19 asthma patients), the E-nose system achieved a high accuracy of 93.75% based on the full time-series response stage. Notably, the accuracy of the early-response stage reached 92.85%, validating the feasibility of rapid diagnosis by using early-response segments. These results demonstrate that the artificial olfactory system based on metal-functionalized porous In2O3 nanorods has great potential in the precise and non-invasive diagnosis of asthma. It also offers useful guidance for rapid detection, even when sensors with slow response and recovery times are employed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AsthmaNitric OxideElectronic NoseHumansBiomarkersNanotubesPlatinumPalladiumLimit of DetectionSmellBreath TestsIndium

Stichwörter der Autor:innen

PtPd decorationasthmaelectronic nose (E-nose)porous In2O3 nanorodsresponse transient-aware learning

Substanzen

BiomarkersNitric Oxideindium oxidePlatinumPalladiumIndium

Autor:innen und Institutionen

  • NEST Lab, Department of Chemistry, College of Sciences, Shanghai University, Shanghai200444, China.
  • National Institute of Metrology, Beijing100029, China.

ORCID-Profile: Jiaqiang Xu

Förderung

  • National Natural Science Foundation of China
  • China Postdoctoral Science Foundation

Zitieren

APA

Mao, L., Dong, Z., Gao, T., Pan, J., Li, J., Xiao, X., Yang, J., Liu, Y., Hu, Q., & Xu, J. (2026). Response Transient-Aware Artificial Olfaction for Nitrogenous Biomarkers Recognition and Asthma Diagnosis. ACS Sensors. https://doi.org/10.1021/acssensors.6c01518

Vancouver

Mao L, Dong Z, Gao T, Pan J, Li J, Xiao X, et al. Response Transient-Aware Artificial Olfaction for Nitrogenous Biomarkers Recognition and Asthma Diagnosis. ACS Sensors. 2026. doi:10.1021/acssensors.6c01518

BibTeX
@article{Mao2026,
  author = {Mao, Liwen and Dong, Zhenliang and Gao, Tiange and Pan, Jie and Li, Jiaxi and Xiao, Xiaoyang and Yang, Jiaxin and Liu, Yiling and Hu, Qingmin and Xu, Jiaqiang},
  title = {Response Transient-Aware Artificial Olfaction for Nitrogenous Biomarkers Recognition and Asthma Diagnosis},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c01518}
}
Kostenlos starten →