EUVIMEDEUVIMED entdecken
Crossref

Strain Sensor–Integrated Tri-Layer Cantilever with Enhanced Sensitivity and Stability for Quantitative Cardiotoxicity Screening

Ke Liu, Arunkumar Shanmugasundaram, Haolan Sun, Longlong Li, Gowoon Jeong iD, Seong Young Ko, Eung-Sam Kim, Bong-Kee Lee iD, Dong-Weon Lee iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c01331 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Ke Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: MEMS and Nanotechnology Laboratory, School of Mechanical Engineering, Chonnam National University, Gwangju61186, Republic of Korea. Hauptthemen laut MEDLINE: Myocytes, Cardiac, Biosensing Techniques, Cardiotoxicity. Die Arbeit nennt 47 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cantilever-based biosensors provide a powerful approach for monitoring cardiomyocyte contractility, but conventional designs often exhibit baseline bending that compromises sensitivity and limits predictive accuracy in drug screening. Here, we present a tri-layer polymer cantilever biosensing platform integrated with a full-bridge piezoresistive strain sensor for the quantitative measurement of cardiomyocyte contractility. The hybrid KMSF–SU-8–KMSF structure minimizes residual stress and reduces baseline deformation by more than 85% compared to SU-8-only cantilevers. This architecture improves strain transfer to the embedded sensors and achieves a limit of detection of approximately 1.2 kPa, which is lower than that of previously reported cantilever systems. The top KMSF layer functions as both an encapsulation barrier and a tissue-guiding interface, promoting alignment, enhancing sarcomere organization, and increasing connexin-43 expression to support cardiomyocyte maturation. Drug screening further confirms the platform’s predictive accuracy, as the device successfully detects the expected pharmacological effects: verapamil decreases contractile force, isoproterenol increases both force and beat rate, blebbistatin suppresses myofilament activity, and astemizole induces arrhythmic beating consistent with hERG channel blockade. By providing stable, label-free, and high-sensitivity electronic readouts of cardiomyocyte contractility, this platform establishes a robust and scalable solution for preclinical cardiotoxicity testing, disease modeling, and personalized medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Myocytes, CardiacBiosensing TechniquesCardiotoxicityAnimalsDrug Evaluation, PreclinicalHumansPolymersVerapamilIsoproterenol

Stichwörter der Autor:innen

cantilever biosensorcardiomyocyte contractilitycardiotoxicity screeningdrug discovery platformpiezoresistive strain sensortri-layer polymer architecture

Substanzen

PolymersVerapamilIsoproterenol

Autor:innen und Institutionen

  • MEMS and Nanotechnology Laboratory, School of Mechanical Engineering, Chonnam National University, Gwangju61186, Republic of Korea.
  • Advanced Medical Device Research Center for Cardiovascular Disease, Chonnam National University, Gwangju61186, Republic of Korea.
  • Medical Robotics and Intelligent Control Laboratory, School of Mechanical Engineering, Chonnam National University, Gwangju61186, Republic of Korea.
  • Department of Biological Sciences, Institute of Sustainable Ecological Environment, Chonnam National University, Gwangju61186, Republic of Korea.
  • School of Mechanical Engineering, Chonnam National University, Gwangju61186, Republic of Korea.
  • Center for Next-Generation Sensor Research and Development, Chonnam National University, Gwangju61186, Republic of Korea.

ORCID-Profile: Gowoon Jeong, Bong-Kee Lee, Dong-Weon Lee

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Liu, K., Shanmugasundaram, A., Sun, H., Li, L., Jeong, G., Ko, S. Y., Kim, E. S., Lee, B. K., & Lee, D. W. (2026). Strain Sensor–Integrated Tri-Layer Cantilever with Enhanced Sensitivity and Stability for Quantitative Cardiotoxicity Screening. ACS Sensors. https://doi.org/10.1021/acssensors.6c01331

Vancouver

Liu K, Shanmugasundaram A, Sun H, Li L, Jeong G, Ko SY, et al. Strain Sensor–Integrated Tri-Layer Cantilever with Enhanced Sensitivity and Stability for Quantitative Cardiotoxicity Screening. ACS Sensors. 2026. doi:10.1021/acssensors.6c01331

BibTeX
@article{Liu2026,
  author = {Liu, Ke and Shanmugasundaram, Arunkumar and Sun, Haolan and Li, Longlong and Jeong, Gowoon and Ko, Seong Young and Kim, Eung-Sam and Lee, Bong-Kee and Lee, Dong-Weon},
  title = {Strain Sensor–Integrated Tri-Layer Cantilever with Enhanced Sensitivity and Stability for Quantitative Cardiotoxicity Screening},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c01331}
}
Kostenlos starten →