A Sensitive and High-Accuracy Dual-Mode Wireless Sensor with MLP-Based Mutual Inductance Suppression for Ammonia Leak and Soil Environment Detection
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c01262 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Hailiang Miao und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Power Engineering, Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science…. Hauptthemen laut MEDLINE: Ammonia, Wireless Technology, Soil, Environmental Monitoring. Die Arbeit nennt 68 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Real-time and accurate detection of hazardous gases such as ammonia (NH3) is essential for intelligent management in energy and chemical industries, agricultural soil monitoring, food freshness evaluation, and atmospheric pollution control. These deployment scenarios demand explosion-proofing, wire-free operation, compactness, cost-effectiveness, and self-temperature compensation, driving adoption of compact, multi-parameter wireless passive sensors. However, multi-mode passive sensors face persistent challenges with mutual inductance interference, which degrades measurement accuracy. This study develops a dual-mode inductor–capacitor sensor using a multilayer perceptron (MLP) for simultaneous NH3 and temperature measurement. Two interdigital electrodes connect to different inductor parts, enabling dual-mode sensing with reduced size/cost. Microstructure polydimethylsiloxane@graphene enhances temperature sensitivity to 205.75 kHz °C–1, tripling the non-microstructure value. Phenyl phosphonic acid modification of tungsten oxide boosts room-temperature NH3 response to 4.1%, a threefold improvement. The MLP model effectively mitigates mutual inductance interference, achieving decoupled NH3 and temperature measurements with mean squared errors of 0.73 and 0.18, respectively. The sensor demonstrates promising application for efficient NH3 leak detection in intelligent transmission line inspection and soil environment monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Mechanical and Power Engineering, Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, East China University of Science and Technology, Shanghai200237, China.
- Key Laboratory of Pressure Systems and Safety, Ministry of Eduction, East China University of Science and Technology, Shanghai200237, China.
- School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai201620, China.
- Engineering Research Center for Nanophotonics & Advanced Instrument, Ministry of Education, East China Normal University, Shanghai200062, China.
- Ningbo Special Equipment Inspection and Research Institute, Ningbo315040, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Miao, H., Cheng, W., Chen, K., Zhou, C., Gao, Y., Ling, X., Wang, T., Chen, Y., Chen, W., & Xuan, F. (2026). A Sensitive and High-Accuracy Dual-Mode Wireless Sensor with MLP-Based Mutual Inductance Suppression for Ammonia Leak and Soil Environment Detection. ACS Sensors. https://doi.org/10.1021/acssensors.6c01262
Vancouver
Miao H, Cheng W, Chen K, Zhou C, Gao Y, Ling X, et al. A Sensitive and High-Accuracy Dual-Mode Wireless Sensor with MLP-Based Mutual Inductance Suppression for Ammonia Leak and Soil Environment Detection. ACS Sensors. 2026. doi:10.1021/acssensors.6c01262
BibTeX
@article{Miao2026,
author = {Miao, Hailiang and Cheng, Weiwei and Chen, Ke and Zhou, Chaoyong and Gao, Yang and Ling, Xiaofeng and Wang, Tao and Chen, Yang and Chen, Wenfei and Xuan, Fuzhen},
title = {A Sensitive and High-Accuracy Dual-Mode Wireless Sensor with MLP-Based Mutual Inductance Suppression for Ammonia Leak and Soil Environment Detection},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c01262}
}
EUVIMED