EUVIMEDEUVIMED entdecken
Crossref

Flying Droplet Sensor Based on H-GQDs/CNF Network Structure and Its Applications

Jiaqi Lu, Xiangdong Chen iD, Xing Ding, Yanchang Liu, Jialun Zhong, Fang Liu, Han Li, Guoping Li

ACS Sensors · 24.07.2026 · 11 (7) · 6157-6166

DOI: 10.1021/acssensors.6c01218 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 10.07.2026. Verfasst von Jiaqi Lu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Information Science and Technology, Southwest Jiaotong University, Chengdu611756, China. Hauptthemen laut MEDLINE: Cough, Quantum Dots, Graphite, Nanofibers. Die Arbeit nennt 38 Literaturangaben. Gefördert von: National Key Research and Development Program of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Respiratory infectious diseases continue to pose a serious threat to public health. Their transmission relies on respiratory droplets that are small in size and evaporate rapidly, making real-time monitoring difficult. In this study, we propose a flying droplet sensor based on hydroxylated graphene quantum dots (H-GQDs) deposited on a cellulose nanofiber (CNF) film. Owing to the network water-locking structure of the film, the sensor is capable of detecting coughing droplets transmitting over long distances (≥2.4 m). By placing multiple such sensors at equal intervals along the cough airflow direction, the spatiotemporal transmission features of coughing droplets were obtained, including arrival time and signal intensity at different distances. On this basis, we investigated the transmission behavior of cough droplets from multiple individuals at various distances. The results show that regions close to the volunteer’s mouth exhibit a broader droplet size distribution, whereas at longer distances, the remaining droplets are mainly composed of small-size and low-intensity components. We further found that coughing droplets typically take 4−5 s to travel more than 2 m, indicating that a time window for timely protection still exists at this distance. In addition, the relationships between cough sound level and droplet signal intensity as well as transmission time were evaluated. No clear correlation was observed, suggesting that acoustic indicators alone cannot directly reflect the infection risk associated with cough droplet transmission. This study provides important insights for the real-time monitoring and protection against respiratory droplet transmission.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CoughQuantum DotsGraphiteNanofibersCelluloseHumans

Stichwörter der Autor:innen

CNFH-GQDsdroplet sensorrespiratory droplet detectionrespiratory droplet spread

Substanzen

GraphiteCellulose

Autor:innen und Institutionen

  • School of Information Science and Technology, Southwest Jiaotong University, Chengdu611756, China.
  • Department of Respiratory and Critical Care Medicine, The Third People's Hospital of Chengdu, Affiliated Hospital of Southwest Jiaotong University, Chengdu610014, China.

ORCID-Profile: Xiangdong Chen

Förderung

  • National Key Research and Development Program of China

Zitieren

APA

Lu, J., Chen, X., Ding, X., Liu, Y., Zhong, J., Liu, F., Li, H., & Li, G. (2026). Flying Droplet Sensor Based on H-GQDs/CNF Network Structure and Its Applications. ACS Sensors, 11(7), 6157-6166. https://doi.org/10.1021/acssensors.6c01218

Vancouver

Lu J, Chen X, Ding X, Liu Y, Zhong J, Liu F, et al. Flying Droplet Sensor Based on H-GQDs/CNF Network Structure and Its Applications. ACS Sensors. 2026;11(7):6157-6166. doi:10.1021/acssensors.6c01218

BibTeX
@article{Lu2026,
  author = {Lu, Jiaqi and Chen, Xiangdong and Ding, Xing and Liu, Yanchang and Zhong, Jialun and Liu, Fang and Li, Han and Li, Guoping},
  title = {Flying Droplet Sensor Based on H-GQDs/CNF Network Structure and Its Applications},
  journal = {ACS Sensors},
  year = {2026},
  volume = {11},
  number = {7},
  pages = {6157--6166},
  doi = {10.1021/acssensors.6c01218}
}
Kostenlos starten →