Rh-Induced Oxygen Vacancies in a PdRh/SnO2 Heterointerface for Enhanced MEMS Hydrogen Detection
ACS Sensors · 28.08.2026 · 11 (8) · 6945-6956
DOI: 10.1021/acssensors.6c01089 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 11.07.2026. Verfasst von Haichao Xiong und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai201620, China. Hauptthemen laut MEDLINE: Hydrogen, Tin Compounds, Oxygen, Micro-Electrical-Mechanical Systems. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
High-performance hydrogen (H2) sensors are essential for industrial safety and environmental monitoring. Herein, we report a microelectromechanical system (MEMS) H2 sensor based on SnO2 nanoflowers in situ decorated with PdRh nanoparticles (PdRh/SnO2). Gas-sensing evaluations demonstrate that the sensor exhibits an ultrahigh response (Ra/Rg) of 20.2 to 100 ppm H2, representing a nearly 4-fold enhancement compared to the conventional Pd/SnO2 sensor. Furthermore, it displays rapid response and recovery times of merely 1.7 and 2.2 s, equivalent to ∼63 and ∼34% of those exhibited by the Pd/SnO2 counterpart, respectively. Additionally, the device achieves a notably low detection limit below 100 ppb alongside good long-term stability. Mechanistic studies combining experiments and density functional theory (DFT) calculations reveal that this significant performance enhancement originates from a dual mechanism. While the synergistic catalytic dissociation of H2 by the PdRh nanoalloy contributes to the improved sensing kinetics, we uncover a more critical role of Rh: it lowers the desorption energy barrier of lattice oxygen in SnO2, thereby inducing the formation of high-density oxygen vacancies at the heterointerface. This Rh-mediated defect engineering promotes the adsorption and generation of reactive oxygen species, providing abundant active sites for H2 reactions and substantially amplifying the sensing response. Finally, the PdRh/SnO2-based MEMS sensor was successfully integrated into a portable wireless monitoring system, validating its tremendous potential for H2 detection applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Materials Science and Engineering, Shanghai University of Engineering Science, Shanghai201620, China.
- Shanghai Key Laboratory of Intelligent Sensing and Detection Technology, School of Mechanical and Power Engineering, East China University of Science and Technology, Shanghai200237, China.
- School of Integrated Circuits (School of Information Science and Electronic Engineering), Shanghai Jiao Tong University, Shanghai200240, China.
- School of Mechanical and Automotive Engineering, Shanghai University of Engineering Science, Shanghai201620, China.
- Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences , Shanghai200050, China.
ORCID-Profile: Shusheng Xu, Tao Wang, Xuerong Shi, Ming Li
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Xiong, H., Xu, S., Wang, T., Ni, W., Wang, Z., Chen, Y., Shi, X., Zhao, L., & Li, M. (2026). Rh-Induced Oxygen Vacancies in a PdRh/SnO2 Heterointerface for Enhanced MEMS Hydrogen Detection. ACS Sensors, 11(8), 6945-6956. https://doi.org/10.1021/acssensors.6c01089
Vancouver
Xiong H, Xu S, Wang T, Ni W, Wang Z, Chen Y, et al. Rh-Induced Oxygen Vacancies in a PdRh/SnO2 Heterointerface for Enhanced MEMS Hydrogen Detection. ACS Sensors. 2026;11(8):6945-6956. doi:10.1021/acssensors.6c01089
BibTeX
@article{Xiong2026,
author = {Xiong, Haichao and Xu, Shusheng and Wang, Tao and Ni, Wangze and Wang, Zhaozhao and Chen, Yiting and Shi, Xuerong and Zhao, Lipeng and Li, Ming},
title = {Rh-Induced Oxygen Vacancies in a PdRh/SnO2 Heterointerface for Enhanced MEMS Hydrogen Detection},
journal = {ACS Sensors},
year = {2026},
volume = {11},
number = {8},
pages = {6945--6956},
doi = {10.1021/acssensors.6c01089}
}
EUVIMED