EUVIMEDEUVIMED entdecken
Crossref

Polyelectrolyte Biosensor Droplets Prepared from Uniform-Sized Liquid-Crystal Shell Templates

Ha-Neul Jang, Soo-Young Park iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c00842 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Ha-Neul Jang und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Polymer Science & Engineering, Polymeric Nano Materials Laboratory, Kyungpook National University, Daegu41566, Republic of Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Liquid Crystals, Glucose, Acrylic Resins. Die Arbeit nennt 36 Literaturangaben. Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Poly(acrylic acid) (PAA) droplets immobilized with 3-aminophenylboronic acid (APBA) (PAAAPBA) were developed for nonenzymatic glucose sensing by monitoring their size changes in glucose solutions. Their sensing performance was compared with that of glucose oxidase-immobilized PAA (PAAGOx) droplets. The PAA-based biosensor droplets were fabricated via simple hatching from uniform-sized shell templates composed of solid-state liquid crystals with uniform pores without using any production instruments. The solid-state liquid crystal shell templates are initially fabricated using glass capillary microfluidic devices; however, once prepared, the subsequent hatching process to generate PAA droplets can be performed on demand without the need for complex microfluidic set-ups. APBA was immobilized onto the PAA droplets via direct N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide coupling. The NaCl-treated PAAAPBA (PAAAPBA/Na) droplets rapidly shrank to the saturated size within 30 min, and the shrinkage ratio exhibited a strong dependence on the glucose concentration (Cg). The NaOH-treated PAAGOx (PAAGOx/Na) droplets exhibited continuous size reduction to a nearly identical size regardless of Cg; however, the size reduction rate was strongly dependent on Cg. The PAAAPBA/Na droplets were used as a glucose biosensor by measuring their diameter ratio, achieving a detection limit of 0.624 mM and a linear range of 1–12 mM. Conversely, the PAAGOx/Na droplets were used as a glucose biosensor by measuring their size reduction rate, yielding a detection limit of 0.733 mM and a linear range of 1–10 mM. Overall, the PAAAPBA/Na droplets offer superior accuracy and convenience compared to the PAAGOx/Na droplets because their size rapidly decreases to a glucose-dependent value, whereas the PAAGOx/Na droplet size requires continuous temporal monitoring to determine the reduction rate. Furthermore, the nonenzymatic PAAAPBA/Na droplet biosensor demonstrates good selectivity, stability, and sensitivity in detecting glucose in human blood and serum.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesLiquid CrystalsGlucoseAcrylic ResinsBoronic AcidsGlucose OxidaseParticle Size

Stichwörter der Autor:innen

biosensorbloodglucosemicrofluidicsnonenzymaticpolyelectrolyteserum

Substanzen

GlucoseBoronic AcidsAcrylic Resinscarbopol 940Glucose Oxidase3-aminobenzeneboronic acid

Autor:innen und Institutionen

  • Department of Polymer Science & Engineering, Polymeric Nano Materials Laboratory, Kyungpook National University, Daegu41566, Republic of Korea.

ORCID-Profile: Soo-Young Park

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Jang, H. N., & Park, S. Y. (2026). Polyelectrolyte Biosensor Droplets Prepared from Uniform-Sized Liquid-Crystal Shell Templates. ACS Sensors. https://doi.org/10.1021/acssensors.6c00842

Vancouver

Jang HN, Park SY. Polyelectrolyte Biosensor Droplets Prepared from Uniform-Sized Liquid-Crystal Shell Templates. ACS Sensors. 2026. doi:10.1021/acssensors.6c00842

BibTeX
@article{Jang2026,
  author = {Jang, Ha-Neul and Park, Soo-Young},
  title = {Polyelectrolyte Biosensor Droplets Prepared from Uniform-Sized Liquid-Crystal Shell Templates},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c00842}
}
Kostenlos starten →