EUVIMEDEUVIMED entdecken
Crossref

Development and Assessment of Poly(ethylene glycol) Diacrylate-Embedded Metalloporphyrin for Phosphorescence Lifetime-Based In Vivo Monitoring of Oxygen Tension

Mohamed M Ibrahim iD, Ryan M Schweller, Mahmoud Mohammed, Yusong Bai, Bruce Klitzman

ACS Sensors · 2026

DOI: 10.1021/acssensors.6c00650 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Mohamed M Ibrahim und 4 weiteren Autor:innen. Beteiligte Einrichtung: Division of Plastic and Reconstructive Surgery, Department of Surgery, Duke University School of Medicine, Durham, North Carolina27710, United States. Hauptthemen laut MEDLINE: Polyethylene Glycols, Metalloporphyrins, Oxygen, Luminescent Measurements. Die Arbeit nennt 28 Literaturangaben. Gefördert von: NHLBI NIH HHS, Plastic Surgery Foundation, Duke University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The timely detection of ischemia is crucial for enhancing outcomes in reconstructive surgery. This study presents the development and in vivo evaluation of a metalloporphyrin-based phosphorescence lifetime oxygen sensor embedded in poly(ethylene glycol) diacrylate (PEGDA) hydrogel for monitoring local tissue oxygen tension (TOT). Palladium(II) tetraphenyltetrabenzoporphyrin was incorporated into microporous PEGDA hydrogels using polystyrene to facilitate dispersion and enhance photophysical properties. Sensors were calibrated under controlled oxygen conditions and characterized for oxygen-dependent phosphorescence lifetime response. In vivo performance was assessed using rat flap models and a swine tongue ischemia model. Implant localization and local tissue response were evaluated using luminescence imaging and histological analysis. The sensors demonstrated an inverse relationship between phosphorescence lifetime and pO2, with a dynamic response to experimentally varied oxygen conditions. In vivo, the sensors detected regional oxygen differences associated with ischemia and areas that later developed tissue necrosis in flap models. In the rat pedicle flap model, a decrease in oxygenation was detected within approximately 70 s of vascular clamping. In the swine tongue model, sensors detected acute oxygenation changes during vascular compromise and partial recovery after tourniquet release and tongue massage. Implants remained localized without visible migration, and histological analysis showed no granulomatous inflammation or multinucleated giant-cell reaction over the 28-day study period. This injectable PEGDA-embedded metalloporphyrin sensor enables non-invasive phosphorescence lifetime-based monitoring of local tissue oxygen tension after implantation. Its oxygen-responsive lifetime behavior, short-term positional stability, and proof-of-concept ischemia detection support further development as a localized monitoring tool for surgical tissue viability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyethylene GlycolsMetalloporphyrinsOxygenLuminescent MeasurementsAnimalsRatsSwineHydrogelsIschemia

Stichwörter der Autor:innen

PEGDAinjectable hydrogeloxygen biosensorphosphorescence lifetimeporphyrintissue ischemia

Substanzen

Polyethylene GlycolsMetalloporphyrinsOxygenpoly(ethylene glycol)diacrylateHydrogels

Autor:innen und Institutionen

  • Division of Plastic and Reconstructive Surgery, Department of Surgery, Duke University School of Medicine, Durham, North Carolina27710, United States.
  • Department of Medicine, University of Maryland School of Medicine, Baltimore, Maryland21202, United States.
  • Department of Plastic and Reconstructive Surgery, Erasmus MC Cancer Institute, University Medical Center Rotterdam, 3015Rotterdam, The Netherlands.
  • Department of Biomedical Engineering, Duke University, Durham, North Carolina27710, United States.
  • Department of Chemistry, Duke University, Durham, North Carolina27710, United States.

ORCID-Profile: Mohamed M Ibrahim

Förderung

  • NHLBI NIH HHS
  • Plastic Surgery Foundation
  • Duke University
  • National Heart, Lung, and Blood Institute
  • Kenan Plastic Surgery Research Labs

Zitieren

APA

Ibrahim, M. M., Schweller, R. M., Mohammed, M., Bai, Y., & Klitzman, B. (2026). Development and Assessment of Poly(ethylene glycol) Diacrylate-Embedded Metalloporphyrin for Phosphorescence Lifetime-Based In Vivo Monitoring of Oxygen Tension. ACS Sensors. https://doi.org/10.1021/acssensors.6c00650

Vancouver

Ibrahim MM, Schweller RM, Mohammed M, Bai Y, Klitzman B. Development and Assessment of Poly(ethylene glycol) Diacrylate-Embedded Metalloporphyrin for Phosphorescence Lifetime-Based In Vivo Monitoring of Oxygen Tension. ACS Sensors. 2026. doi:10.1021/acssensors.6c00650

BibTeX
@article{Ibrahim2026,
  author = {Ibrahim, Mohamed M and Schweller, Ryan M and Mohammed, Mahmoud and Bai, Yusong and Klitzman, Bruce},
  title = {Development and Assessment of Poly(ethylene glycol) Diacrylate-Embedded Metalloporphyrin for Phosphorescence Lifetime-Based In Vivo Monitoring of Oxygen Tension},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.6c00650}
}