A Diffusion-Driven Chromogenic Reagent-Free Viscosity-Based Sensor with Dual Signals for the Visual Detection of Hyaluronidase
ACS Sensors · 2026
DOI: 10.1021/acssensors.6c00293 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Yanhui Bi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan, Shandong 250014, China. Hauptthemen laut MEDLINE: Hyaluronoglucosaminidase, Biosensing Techniques. Die Arbeit nennt 50 Literaturangaben. Gefördert von: Taishan Scholar Project of Shandong Province, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Point-of-care testing (POCT) requires simple and cost-effective strategies to enhance reliability and practicality. Here, a state-of-the-art, dual-mode viscosity-based sensor (DM vis-sensor) is developed by leveraging the diffusion-driven viscosity differentiation on the mesoporous membrane. The rapid and visual detection of hyaluronidase (HAase) is demonstrated as a model. The sensor exploits the enzymatic cleavage of hyaluronic acid (HA) by HAase, which reduces solution viscosity, thereby altering the solution diffusion pattern on the mesoporous membrane. High-viscosity HA solutions form small and dark diffusion spots with short diameters and low grayscale ratio (GR) values, while HAase-treated HA solutions yield large and light diffusion spots with long diameters and high GR values. This dual-mode sensor, which combines distance and color readouts, enables intuitive and instrument-free detection of HAase without the need of chromogenic agents. It demonstrates high sensitivity to HAase, with detection limits of 0.12 U/mL (distance-based readout) and 0.16 U/mL (grayscale-based readout). Additionally, it is successfully validated through the quantification of HAase in human urine samples. Notably, its simplicity, low cost, and dual-readout reliability make it a promising POCT tool for early diagnosis and monitoring, especially in resource-limited settings. Therefore, this work highlights the potential of the development of dual-mode viscosity-based sensors for POCT applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Qilu University of Technology (Shandong Academy of Sciences), Shandong Analysis and Test Center, Jinan, Shandong 250014, China.
- School of Pharmaceutical Sciences, Qilu University of Technology (Shandong Academy of Sciences), Jinan, Shandong 250014, China.
- School of Chemistry and Chemical Engineering, Qilu Normal University, Jinan, Shandong 250200, China.
- College of Pharmacy, Seoul National University, Seoul 08826, Republic of Korea.
- Department of Chemistry, Beijing Key Laboratory of Microanalytical Methods and Instrumentation, Key Laboratory of Bioorganic Phosphorus Chemistry & Chemical Biology (Ministry of Education), Tsinghua University, Beijing…
ORCID-Profile: Mei Zhao, Wenli Wu, Zhongxing Wang, Jin-Ming Lin, Qiongzheng Hu
Förderung
- Taishan Scholar Project of Shandong Province
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
- Science, Education, and Industry Integration Pilot Project for Talent Research, Qilu University of Technology
- Innovation Team Project of Jinan
Zitieren
APA
Bi, Y., Zhao, M., Wu, W., Yin, F., Wang, Z., Cheng, R., Lin, J. M., & Hu, Q. (2026). A Diffusion-Driven Chromogenic Reagent-Free Viscosity-Based Sensor with Dual Signals for the Visual Detection of Hyaluronidase. ACS Sensors. https://doi.org/10.1021/acssensors.6c00293
Vancouver
Bi Y, Zhao M, Wu W, Yin F, Wang Z, Cheng R, et al. A Diffusion-Driven Chromogenic Reagent-Free Viscosity-Based Sensor with Dual Signals for the Visual Detection of Hyaluronidase. ACS Sensors. 2026. doi:10.1021/acssensors.6c00293
BibTeX
@article{Bi2026,
author = {Bi, Yanhui and Zhao, Mei and Wu, Wenli and Yin, Fangchao and Wang, Zhongxing and Cheng, Ranran and Lin, Jin-Ming and Hu, Qiongzheng},
title = {A Diffusion-Driven Chromogenic Reagent-Free Viscosity-Based Sensor with Dual Signals for the Visual Detection of Hyaluronidase},
journal = {ACS Sensors},
year = {2026},
doi = {10.1021/acssensors.6c00293}
}
EUVIMED