Photothermal Recycling Biosensing for Continuous, Sensitive Molecular Quantification
ACS Sensors · 28.08.2026 · 11 (8) · 6748-6759
DOI: 10.1021/acssensors.6c00172 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 29.05.2026. Verfasst von Yongchen Tai und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida32611, United States. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: NIGMS NIH HHS, Division of Chemical, Bioengineering, Environmental, and Transport Systems, NIBIB NIH HHS.
Abstract (Originalsprache)
Continuous biochemical sensing provides valuable insights into an individual’s physiological state and the mechanisms underlying pathophysiological changes. However, most existing bioanalytical methods are not compatible with continuous biochemical sensing. A major technical challenge lies in achieving rapid measurement readouts while maintaining high specificity and sensitivity in complex biological fluids. Sensitive molecular detection typically requires slow analyte–binder dissociation and long incubation to reach equilibrium, whereas rapid and frequent measurements demand fast association–dissociation kinetics that are difficult to reconcile for low-abundance analytes. To address this challenge, we introduce a sensing mechanism termed photothermal recycling (PTR), which mimics the thermal cycling process in polymerase chain reactions. Using plasmonic photothermal effects, PTR rapidly recycles binders to enable frequent measurements. We demonstrate a digital PTR assay capable of multi-hour biochemical monitoring with sub-picomolar (pM) sensitivity in buffer, diluted serum, and saliva. This approach leverages localized thermal energy to dynamically modulate biomolecular recognition, offering a new bioanalytical paradigm for continuous biochemical sensing across diverse application settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, Florida32611, United States.
- Department of Mechanical and Aerospace Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong SAR999077, China.
- Department of Pediatrics, University of Florida, Gainesville, Florida32610, United States.
- Department of Chemical Engineering, University of Florida, Gainesville, Florida32611, United States.
ORCID-Profile: Ziyan Qian, Carl Denard, Jing Pan
Förderung
- NIGMS NIH HHS
- Division of Chemical, Bioengineering, Environmental, and Transport Systems
- NIBIB NIH HHS
- University of Florida
- National Institute of Biomedical Imaging and Bioengineering
Zitieren
APA
Tai, Y., Li, Y., Wang, W., Lu, Y., Qian, Z., Conover, M., Neu, J., Denard, C., Zheng, Q., & Pan, J. (2026). Photothermal Recycling Biosensing for Continuous, Sensitive Molecular Quantification. ACS Sensors, 11(8), 6748-6759. https://doi.org/10.1021/acssensors.6c00172
Vancouver
Tai Y, Li Y, Wang W, Lu Y, Qian Z, Conover M, et al. Photothermal Recycling Biosensing for Continuous, Sensitive Molecular Quantification. ACS Sensors. 2026;11(8):6748-6759. doi:10.1021/acssensors.6c00172
BibTeX
@article{Tai2026,
author = {Tai, Yongchen and Li, Yunshen and Wang, Wenting and Lu, Yang and Qian, Ziyan and Conover, Mitchell and Neu, Josef and Denard, Carl and Zheng, Qiye and Pan, Jing},
title = {Photothermal Recycling Biosensing for Continuous, Sensitive Molecular Quantification},
journal = {ACS Sensors},
year = {2026},
volume = {11},
number = {8},
pages = {6748--6759},
doi = {10.1021/acssensors.6c00172}
}
EUVIMED