EUVIMEDEUVIMED entdecken
Crossref

Flow Plastometry of Microplastics Using Optical Line Tweezers

Jee Won Lee, Subeen Park, Jin Il Jang iD, Jae Hun Kim iD, Hyung Min Kim iD

ACS Sensors · 27.03.2026 · 11 (3) · 2101-2110

DOI: 10.1021/acssensors.5c03772 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 13.02.2026. Verfasst von Jee Won Lee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Kookmin University, Seoul 02707, Republic of Korea. Hauptthemen laut MEDLINE: Microplastics, Optical Tweezers, Water Pollutants, Chemical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Ministry of Science and ICT, South Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microplastics (MPs), both primary and secondary, have been reported to cause adverse effects on ecosystems, including human health. A substantial portion of MPs has been identified in aquatic environments such as oceans, rivers, lakes, reservoirs, and even drinking water systems. The potential human health risks of MPs absorbed through water intake have been increasingly reported. The chemical composition, which includes core components and surface coatings, as well as physical characteristics such as size and shape, collectively determines their toxicity. However, preparation steps such as density separation, digestion, and filtration can chemically modify microplastics and cause matrix interference, necessitating the development of advanced analytical methods. This study introduces a novel system employing Raman line monitoring and trapping system to achieve simultaneous morphological and chemical analysis of MPs in a flow channel. Furthermore, we developed a protocol for acquiring Raman signals from particles as small as 500 nm through precise optical immobilization. Our approach can provide a powerful tool for real-time monitoring and characterization of MPs in aquatic environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroplasticsOptical TweezersWater Pollutants, ChemicalSpectrum Analysis, Raman

Stichwörter der Autor:innen

line tweezermicrofluidicsmicroplastics analysisoptical tweezerraman spectroscopy

Substanzen

MicroplasticsWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Chemistry, Kookmin University, Seoul 02707, Republic of Korea.
  • Nanophotonic System Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.

ORCID-Profile: Jin Il Jang, Jae Hun Kim, Hyung Min Kim

Förderung

  • Ministry of Science and ICT, South Korea

Zitieren

APA

Lee, J. W., Park, S., Jang, J. I., Kim, J. H., & Kim, H. M. (2026). Flow Plastometry of Microplastics Using Optical Line Tweezers. ACS Sensors, 11(3), 2101-2110. https://doi.org/10.1021/acssensors.5c03772

Vancouver

Lee JW, Park S, Jang JI, Kim JH, Kim HM. Flow Plastometry of Microplastics Using Optical Line Tweezers. ACS Sensors. 2026;11(3):2101-2110. doi:10.1021/acssensors.5c03772

BibTeX
@article{Lee2026,
  author = {Lee, Jee Won and Park, Subeen and Jang, Jin Il and Kim, Jae Hun and Kim, Hyung Min},
  title = {Flow Plastometry of Microplastics Using Optical Line Tweezers},
  journal = {ACS Sensors},
  year = {2026},
  volume = {11},
  number = {3},
  pages = {2101--2110},
  doi = {10.1021/acssensors.5c03772}
}
Kostenlos starten →