EUVIMEDEUVIMED entdecken
Crossref

Highly Reliable Dimethyl Disulfide Chemiresistive Gas Sensor Based on Vacancy-Engineered MoO 3 Nanobelts for Complex Odor Monitoring and Field Testing

Myeong Doo Ryu, Yeonjin Je, Yeongsik Hwa, Na Young Choi, Hyunsung Jung, Soong Ju Oh iD, Sang-Soo Chee iD

ACS Sensors · 2026

DOI: 10.1021/acssensors.5c01505 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2026. Verfasst von Myeong Doo Ryu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Nano Convergence Materials Center, Korea Institute of Ceramic Engineering and Technology (KICET), 101 Soho-ro, Jinju 52851, Republic of Korea. Hauptthemen laut MEDLINE: Odorants, Disulfides, Molybdenum, Oxides. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: National Research Foundation of Korea, Ministry of Trade, Industry and Energy.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dimethyl disulfide (DMDS) is an odorous sulfur-containing volatile organic compound primarily emitted from sewage treatment plants. However, most metal-oxide-based DMDS gas sensors have been limited to parts-per-million-level performance despite the fact that DMDS can cause severe health concerns and produce an unpleasant smell even at ppb-level concentrations. Previous studies have primarily focused on enhancing the DMDS gas response via vacancy engineering without addressing the gas reliability. Here, we explored a MoO3-based DMDS gas sensor and the correlation between detection performance and vacancy concentration through an oxygen annealing process. As the annealing temperature increased, the DMDS gas response decreased, whereas the baseline resistance remained stable. Additionally, the sensor exhibited a 34-fold improvement in gas repeatability and a 20% faster recovery time compared to nonannealed MoO3. This can be attributed to the reduced number of bound gas molecules on the vacancies. We finally conducted an odorous gas sensing test collected at a sewage treatment plant for the first time. We achieved a clear gas response, closely matching values obtained from standard gas cylinders with identical concentrations. This study provides insight into the design of metal-oxide-based gas sensors for constructing a practical odor monitoring system.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OdorantsDisulfidesMolybdenumOxidesGasesNanostructures

Stichwörter der Autor:innen

MoO3complex odordimethyl disulfidegas sensoroxygen vacancy

Substanzen

DisulfidesMolybdenumdimethyl disulfideOxidesmolybdenum trioxideGases

Autor:innen und Institutionen

  • Nano Convergence Materials Center, Korea Institute of Ceramic Engineering and Technology (KICET), 101 Soho-ro, Jinju 52851, Republic of Korea.
  • Department of Materials Science and Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
  • Department of Nanoenergy Engineering, Pusan National University (PNU), 2 Busandaehak-ro 63beon-gil, Geumjeong-gu, Busan 46241, Republic of Korea.

ORCID-Profile: Soong Ju Oh, Sang-Soo Chee

Förderung

  • National Research Foundation of Korea
  • Ministry of Trade, Industry and Energy

Zitieren

APA

Ryu, M. D., Je, Y., Hwa, Y., Choi, N. Y., Jung, H., Oh, S. J., & Chee, S. S. (2026). Highly Reliable Dimethyl Disulfide Chemiresistive Gas Sensor Based on Vacancy-Engineered MoO 3 Nanobelts for Complex Odor Monitoring and Field Testing. ACS Sensors. https://doi.org/10.1021/acssensors.5c01505

Vancouver

Ryu MD, Je Y, Hwa Y, Choi NY, Jung H, Oh SJ, et al. Highly Reliable Dimethyl Disulfide Chemiresistive Gas Sensor Based on Vacancy-Engineered MoO 3 Nanobelts for Complex Odor Monitoring and Field Testing. ACS Sensors. 2026. doi:10.1021/acssensors.5c01505

BibTeX
@article{Ryu2026,
  author = {Ryu, Myeong Doo and Je, Yeonjin and Hwa, Yeongsik and Choi, Na Young and Jung, Hyunsung and Oh, Soong Ju and Chee, Sang-Soo},
  title = {Highly Reliable Dimethyl Disulfide Chemiresistive Gas Sensor Based on Vacancy-Engineered MoO 3 Nanobelts for Complex Odor Monitoring and Field Testing},
  journal = {ACS Sensors},
  year = {2026},
  doi = {10.1021/acssensors.5c01505}
}
Kostenlos starten →