Branch Enhanced Photoacoustic Sensor for Comprehensive Sevoflurane Monitoring
ACS Sensors · 25.04.2025 · 10 (4) · 2598-2608
DOI: 10.1021/acssensors.4c03063 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 10.02.2025. Verfasst von Xueshi Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Optoelectronic Engineering, Xidian University, Xi'an 710071, China. Hauptthemen laut MEDLINE: Sevoflurane, Photoacoustic Techniques, Anesthetics, Inhalation. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Key Laboratory of Energetic Materials, China.
Abstract (Originalsprache)
Comprehensive sevoflurane monitoring (CSM, sevoflurane concentrations from parts per billion to percent) is essential for the therapeutic diagnosis of anesthetized patients and occupational exposure monitoring. Photoacoustic spectroscopy, with its advantages of high sensitivity, wide dynamic range, miniaturization, and real-time, holds unique potential for CSM. A highly sensitive resonator with a small volume is an optimal choice regarding the limited exhaled gas amount. Wavelength modulation is not suitable for detecting trace sevoflurane with broad absorption lines because the modulation depth is far from optimal. Sensitive detection can be achieved using chopper-based amplitude modulation; therefore, a relatively low resonance frequency is critical. By the introduction of flexible polyurethane tubes, a branched photoacoustic cell (BPAC) was developed to compensate for the contradiction between the miniaturized resonator and the low resonance frequency requirement. The resonance frequency of BPAC was as low as 1036 Hz at a compact capacity of only 2.7 mL. Taking advantage of the replaceable and flexible branches, the geometry, resonance frequency, and sensitivity of BPAC could be optimized. The BPAC decoupling of the excitation and absorption paths, therefore, avoided the degradation of thermal-acoustic coupling at high concentrations. The sevoflurane detection results demonstrated that the Branch Enhanced Photoacoustic Spectroscopy (BEPAS) sensor yielded a 1σ limit of detection of 1.61 ppb with a 3 s integration time, corresponding to a normalized noise equivalent absorption coefficient of 2.2 × 10 –9 cm –1 WHz –1/2 . With only a 1 cm long absorption path and high thermal-acoustic coupling, the BEPAS sensor provided a wide dynamic range of 1.61 ppb to 8% (154 dB). Continuous on-site testing for CSM issues was performed, which demonstrated the stability and reliability of this sensor. The developed BEPAS may open new avenues for low resonance frequency, ultrasensitivity, wide dynamic range, and compact large-molecule gas detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Optoelectronic Engineering, Xidian University, Xi'an 710071, China.
- Department of Pharmacy, Department of Anesthesiology, Xijing Hospital, Air Force Medical University, Xi'an 710032, China.
- Center for Advanced Diffusion-Wave and Photoacoustic Technologies (CADIPT), Department of Mechanical and Industrial Engineering, and Institute for Advanced Non-Destructive and Non-Invasive Diagnostic Technologies (IANDI…
- Hangzhou Institute of Technology, Xidian University, Hangzhou 311231, China.
- State Key Laboratory of Electromechanical Integrated Manufacturing of High-performance Electronic Equipment, Xidian University, Xi'an 710071, China.
ORCID-Profile: Xueshi Zhang, Huiting Huan
Förderung
- National Key Laboratory of Energetic Materials, China
Zitieren
APA
Zhang, X., Yang, Y., Liu, L., Sun, J., Zeng, Y., Yang, Z., Yin, X., Zhao, X., Huan, H., Shao, X., & Mandelis, A. (2025). Branch Enhanced Photoacoustic Sensor for Comprehensive Sevoflurane Monitoring. ACS Sensors, 10(4), 2598-2608. https://doi.org/10.1021/acssensors.4c03063
Vancouver
Zhang X, Yang Y, Liu L, Sun J, Zeng Y, Yang Z, et al. Branch Enhanced Photoacoustic Sensor for Comprehensive Sevoflurane Monitoring. ACS Sensors. 2025;10(4):2598-2608. doi:10.1021/acssensors.4c03063
BibTeX
@article{Zhang2025,
author = {Zhang, Xueshi and Yang, Yufeng and Liu, Lixian and Sun, Jialiang and Zeng, Yi and Yang, Zhifu and Yin, Xukun and Zhao, Xiaoming and Huan, Huiting and Shao, Xiaopeng and Mandelis, Andreas},
title = {Branch Enhanced Photoacoustic Sensor for Comprehensive Sevoflurane Monitoring},
journal = {ACS Sensors},
year = {2025},
volume = {10},
number = {4},
pages = {2598--2608},
doi = {10.1021/acssensors.4c03063}
}
EUVIMED