EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Genetically Encoded Sensor for Real-Time Monitoring of Poly-ADP-Ribosylation Dynamics In Vitro and in Cells

Alix Thomas, Kapil Upadhyaya, Daniel Bejan, Hayden Adoff iD, Michael Cohen iD, Carsten Schultz iD

ACS Sensors · 25.10.2024 · 9 (10) · 5246-5252

DOI: 10.1021/acssensors.4c01406 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 01.10.2024. Verfasst von Alix Thomas und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical Physiology and Biochemistry, Oregon Health and Science University, 3181 SW Sam Jackson Park Rd., L334, Portland, Oregon 97239,…. Hauptthemen laut MEDLINE: Fluorescence Resonance Energy Transfer, Poly ADP Ribosylation. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NINDS NIH HHS, National Institute of Neurological Disorders and Stroke, Oregon Health and Science University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

ADP-ribosylation, the transfer of ADP-ribose (ADPr) from nicotinamide adenine dinucleotide (NAD+) groups to proteins, is a conserved post-translational modification (PTM) that occurs most prominently in response to DNA damage. ADP-ribosylation is a dynamic PTM regulated by writers (PARPs), erasers (ADPr hydrolases), and readers (ADPR binders). PARP1 is the primary DNA damage-response writer responsible for adding a polymer of ADPR to proteins (PARylation). Real-time monitoring of PARP1-mediated PARylation, especially in live cells, is critical for understanding the spatial and temporal regulation of this unique PTM. Here, we describe a genetically encoded FRET probe (pARS) for semiquantitative monitoring of PARylation dynamics. pARS feature a PAR-binding WWE domain flanked with turquoise and Venus. With a ratiometric readout and excellent signal-to-noise characteristics, we show that pARS can monitor PARP1-dependent PARylation temporally and spatially in real-time. pARS provided unique insights into PARP1-mediated PARylation kinetics in vitro and high-sensitivity detection of PARylation in live cells, even under mild DNA damage. We also show that pARS can be used to determine the potency of PARP inhibitors in vitro and, for the first time, in live cells in response to DNA damage. The robustness and ease of use of pARS make it an important tool for the PARP field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescence Resonance Energy TransferPoly ADP RibosylationHumansPoly (ADP-Ribose) Polymerase-1Biosensing TechniquesHEK293 Cells

Stichwörter der Autor:innen

DNA repairFRETfluorescence microscopyposttranslational modificationssignal transduction

Substanzen

Poly (ADP-Ribose) Polymerase-1PARP1 protein, human

Autor:innen und Institutionen

  • Department of Chemical Physiology and Biochemistry, Oregon Health and Science University, 3181 SW Sam Jackson Park Rd., L334, Portland, Oregon 97239, United States.

ORCID-Profile: Hayden Adoff, Michael Cohen, Carsten Schultz

Förderung

  • NINDS NIH HHS
  • National Institute of Neurological Disorders and Stroke
  • Oregon Health and Science University
  • Deutsche Forschungsgemeinschaft

Zitieren

APA

Thomas, A., Upadhyaya, K., Bejan, D., Adoff, H., Cohen, M., & Schultz, C. (2024). A Genetically Encoded Sensor for Real-Time Monitoring of Poly-ADP-Ribosylation Dynamics In Vitro and in Cells. ACS Sensors, 9(10), 5246-5252. https://doi.org/10.1021/acssensors.4c01406

Vancouver

Thomas A, Upadhyaya K, Bejan D, Adoff H, Cohen M, Schultz C. A Genetically Encoded Sensor for Real-Time Monitoring of Poly-ADP-Ribosylation Dynamics In Vitro and in Cells. ACS Sensors. 2024;9(10):5246-5252. doi:10.1021/acssensors.4c01406

BibTeX
@article{Thomas2024,
  author = {Thomas, Alix and Upadhyaya, Kapil and Bejan, Daniel and Adoff, Hayden and Cohen, Michael and Schultz, Carsten},
  title = {A Genetically Encoded Sensor for Real-Time Monitoring of Poly-ADP-Ribosylation Dynamics In Vitro and in Cells},
  journal = {ACS Sensors},
  year = {2024},
  volume = {9},
  number = {10},
  pages = {5246--5252},
  doi = {10.1021/acssensors.4c01406}
}
Kostenlos starten →