EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Application Evaluation and Performance-Directed Improvement of the Native and Engineered Biosensors

Min Li, Zhenya Chen iD, Yi-Xin Huo iD

ACS Sensors · 25.10.2024 · 9 (10) · 5002-5024

DOI: 10.1021/acssensors.4c01072 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift ACS Sensors, online erschienen am 11.10.2024. Verfasst von Min Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology, Aerospace Center Hospital, College of Life Science, Beijing Institute of Technology, Haidian District, No. 5 South Zh…. Hauptthemen laut MEDLINE: Biosensing Techniques, Transcription Factors. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 181 Literaturangaben. Gefördert von: Natural Science Foundation of Hebei Province, National Natural Science Foundation of China, Science and Technology Program of Tangshan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transcription factor (TF)-based biosensors (TFBs) have received considerable attention in various fields due to their capability of converting biosignals, such as molecule concentrations, into analyzable signals, thereby bypassing the dependence on time-consuming and laborious detection techniques. Natural TFs are evolutionarily optimized to maintain microbial survival and metabolic balance rather than for laboratory scenarios. As a result, native TFBs often exhibit poor performance, such as low specificity, narrow dynamic range, and limited sensitivity, hindering their application in laboratory and industrial settings. This work analyzes four types of regulatory mechanisms underlying TFBs and outlines strategies for constructing efficient sensing systems. Recent advances in TFBs across various usage scenarios are reviewed with a particular focus on the challenges of commercialization. The systematic improvement of TFB performance by modifying the constituent elements is thoroughly discussed. Additionally, we propose future directions of TFBs for developing rapid-responsive biosensors and addressing the challenge of application isolation. Furthermore, we look to the potential of artificial intelligence (AI) technologies and various models for programming TFB genetic circuits. This review sheds light on technical suggestions and fundamental instructions for constructing and engineering TFBs to promote their broader applications in Industry 4.0, including smart biomanufacturing, environmental and food contaminants detection, and medical science.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesTranscription FactorsArtificial IntelligenceHumans

Stichwörter der Autor:innen

biosensor improvement strategiesbiosensorsdetection toolsdose−response effectrapid-responsive biosensorsregulation toolsresponse mechanismstranscription factor

Substanzen

Transcription Factors

Autor:innen und Institutionen

  • Department of Gastroenterology, Aerospace Center Hospital, College of Life Science, Beijing Institute of Technology, Haidian District, No. 5 South Zhongguancun Street, Beijing 100081, China.
  • Center for Future Foods, Muyuan Laboratory, 110 Shangding Road, Zhengzhou, Henan 450016, China.

ORCID-Profile: Zhenya Chen, Yi-Xin Huo

Förderung

  • Natural Science Foundation of Hebei Province
  • National Natural Science Foundation of China
  • Science and Technology Program of Tangshan

Zitieren

APA

Li, M., Chen, Z., & Huo, Y. X. (2024). Application Evaluation and Performance-Directed Improvement of the Native and Engineered Biosensors. ACS Sensors, 9(10), 5002-5024. https://doi.org/10.1021/acssensors.4c01072

Vancouver

Li M, Chen Z, Huo YX. Application Evaluation and Performance-Directed Improvement of the Native and Engineered Biosensors. ACS Sensors. 2024;9(10):5002-5024. doi:10.1021/acssensors.4c01072

BibTeX
@article{Li2024,
  author = {Li, Min and Chen, Zhenya and Huo, Yi-Xin},
  title = {Application Evaluation and Performance-Directed Improvement of the Native and Engineered Biosensors},
  journal = {ACS Sensors},
  year = {2024},
  volume = {9},
  number = {10},
  pages = {5002--5024},
  doi = {10.1021/acssensors.4c01072}
}
Kostenlos starten →