EUVIMEDEUVIMED entdecken
Crossref

Ultradense Array of On-Chip Sensors for High-Throughput Electrochemical Analyses

Lucas B Ayres, Gabriel J C Pimentel, Juliana N Y Costa, Maria H O Piazzetta, Angelo L Gobbi, Flávio M Shimizu iD, Carlos D Garcia iD, Renato S Lima iD

ACS Sensors · 2024

DOI: 10.1021/acssensors.4c01026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Lucas B Ayres und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States. Hauptthemen laut MEDLINE: Electrochemical Techniques, Lab-On-A-Chip Devices, COVID-19, SARS-CoV-2. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: South Carolina Department of Agriculture, Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-throughput sensors are valuable tools for enabling massive, fast, and accurate diagnostics. To yield this type of electrochemical device in a simple and low-cost way, high-density arrays of vertical gold thin-film microelectrode-based sensors are demonstrated, leading to the rapid and serial interrogation of dozens of samples (10 μL droplets). Based on 16 working ultramicroelectrodes (UMEs) and 3 quasi-reference electrodes (QREs), a total of 48 sensors were engineered in a 3D crossbar arrangement that devised a low number of conductive lines. By exploiting this design, a compact chip (75 × 35 mm) can enable performing 16 sequential analyses without intersensor interferences by dropping one sample per UME finger. In practice, the electrical connection to the sensors was achieved by simply switching the contact among WE adjacent fingers. Importantly, a short analysis time was ensured by interrogating the UMEs with chronoamperometry or square wave voltammetry using a low-cost and hand-held one-channel potentiostat. As a proof of concept, the detection of Staphylococcus aureus in 15 samples was performed within 14 min (20 min incubation and 225 s reading). Additionally, the implementation of peptide-tethered immunosensors in these chips allowed the screening of COVID-19 from patient serum samples with 100% accuracy. Our experiments also revealed that dispensing additional droplets on the array (in certain patterns) results in the overestimation of the faradaic current signals, a phenomenon referred to as crosstalk. To address this interference, a set of analyses was conducted to design a corrective strategy that boosted the testing capacity by allowing using all on-chip sensors to address subsequent analyses (i.e., 48 samples simultaneously dispensed on the chip). This strategy only required grounding the unused rows of QRE and can be broadly adopted to develop high-throughput UME-based sensors. In practice, we could analyze 48 droplets (with [Fe(CN)6]4-) within ∼8 min using amperometry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesLab-On-A-Chip DevicesCOVID-19SARS-CoV-2HumansMicroelectrodesStaphylococcus aureusGoldBiosensing TechniquesHigh-Throughput Screening Assays

Stichwörter der Autor:innen

amperometryhigh-density arrayhigh-throughput sensorquasi-reference electrodeultramicroelectrode

Substanzen

Gold

Autor:innen und Institutionen

  • Department of Chemistry, Clemson University, Clemson, South Carolina 29634, United States.
  • Brazilian Center for Research in Energy and Materials, Brazilian Nanotechnology National Laboratory, Campinas, São Paulo 13083-970, Brazil.
  • Institute of Chemistry, University of Campinas, Campinas, São Paulo 13083-970, Brazil.
  • Center for Natural and Human Sciences, Federal University of ABC, Santo André, São Paulo 09210-580, Brazil.
  • São Carlos Institute of Chemistry, University of São Paulo, São Carlos, São Paulo 13565-590, Brazil.

ORCID-Profile: Flávio M Shimizu, Carlos D Garcia, Renato S Lima

Förderung

  • South Carolina Department of Agriculture
  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação de Amparo à Pesquisa do Estado de São Paulo
  • Clemson University

Zitieren

APA

Ayres, L. B., Pimentel, G. J. C., Costa, J. N. Y., Piazzetta, M. H. O., Gobbi, A. L., Shimizu, F. M., Garcia, C. D., & Lima, R. S. (2024). Ultradense Array of On-Chip Sensors for High-Throughput Electrochemical Analyses. ACS Sensors. https://doi.org/10.1021/acssensors.4c01026

Vancouver

Ayres LB, Pimentel GJC, Costa JNY, Piazzetta MHO, Gobbi AL, Shimizu FM, et al. Ultradense Array of On-Chip Sensors for High-Throughput Electrochemical Analyses. ACS Sensors. 2024. doi:10.1021/acssensors.4c01026

BibTeX
@article{Ayres2024,
  author = {Ayres, Lucas B and Pimentel, Gabriel J C and Costa, Juliana N Y and Piazzetta, Maria H O and Gobbi, Angelo L and Shimizu, Flávio M and Garcia, Carlos D and Lima, Renato S},
  title = {Ultradense Array of On-Chip Sensors for High-Throughput Electrochemical Analyses},
  journal = {ACS Sensors},
  year = {2024},
  doi = {10.1021/acssensors.4c01026}
}
Kostenlos starten →