EUVIMEDEUVIMED entdecken
Crossref

Band Alignment Modulated Polarity-Switchable PEC Ratiometric Sensor through Coupling a pH-Responsive CuTCPP MOF with i-Motif Sensing tool

Xuechen Zhang, Yanru Zhang, Xue Fan, Wenbo Song iD

ACS Sensors · 2024

DOI: 10.1021/acssensors.4c00608 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Xuechen Zhang und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Jilin University, Changchun 130012, People's Republic of China. Hauptthemen laut MEDLINE: Electrochemical Techniques, Quantum Dots. Die Arbeit wurde bisher 40-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In conventional ratiometric photoelectrochemical (PEC) sensors, the detection and reference signals are output sequentially from two independent photosensitive materials. In such a "two-to-two" ratiometric mode, unavoidable difference during dual-interface modification exists, resulting in questionable ratiometric signals and detection results. To address this issue, we propose a novel "one-to-two" ratiometric PEC sensor on a single electrode interface through pH-modulated band alignment engineering. The double ratiometric signals are generated by the synergistic action of a pH-responsive CuTCPP/WS2 photoelectric substrate material and the i-motif sensing tool. Specifically, a ternary heterostructure to generate a photoanodic detection signal is formed under alkaline conditions between CuTCPP/WS2 and signal label CdS QDs binding to the i-motif. While under acidic conditions, a photocurrent polarity conversion and signaling labels detachment, induced by the band realignment of CuTCPP/WS2 and the i-motif conformational switching, produce a reliable internal reference photocathodic signal. The feasibility of this two-wing signal generation strategy is validated by detecting mycotoxin ochratoxin A, which achieves accurate and reliable ratio detection results. Overall, this work provides guidance for the design of a PEC ratiometric determination system and exhibits great potential to be applied in practical analysis research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesQuantum DotsHydrogen-Ion ConcentrationOchratoxinsMetal-Organic FrameworksCadmium CompoundsSulfidesLimit of DetectionElectrodes

Stichwörter der Autor:innen

PEC ratiometric sensorband alignment engineeringi-motifpH-responsivephotocurrent polarity switching

Substanzen

ochratoxin AOchratoxinsMetal-Organic FrameworksCadmium Compoundscadmium sulfideSulfides

Autor:innen und Institutionen

  • College of Chemistry, Jilin University, Changchun 130012, People's Republic of China.

ORCID-Profile: Wenbo Song

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, X., Zhang, Y., Fan, X., & Song, W. (2024). Band Alignment Modulated Polarity-Switchable PEC Ratiometric Sensor through Coupling a pH-Responsive CuTCPP MOF with i-Motif Sensing tool. ACS Sensors. https://doi.org/10.1021/acssensors.4c00608

Vancouver

Zhang X, Zhang Y, Fan X, Song W. Band Alignment Modulated Polarity-Switchable PEC Ratiometric Sensor through Coupling a pH-Responsive CuTCPP MOF with i-Motif Sensing tool. ACS Sensors. 2024. doi:10.1021/acssensors.4c00608

BibTeX
@article{Zhang2024,
  author = {Zhang, Xuechen and Zhang, Yanru and Fan, Xue and Song, Wenbo},
  title = {Band Alignment Modulated Polarity-Switchable PEC Ratiometric Sensor through Coupling a pH-Responsive CuTCPP MOF with i-Motif Sensing tool},
  journal = {ACS Sensors},
  year = {2024},
  doi = {10.1021/acssensors.4c00608}
}
Kostenlos starten →