Enzymatic Precipitation of Highly Electroactive and Ion-Transporting Prussian Blue for a Sensitive Electrochemical Immunosensor
ACS Sensors · 28.06.2024 · 9 (6) · 3224-3232
DOI: 10.1021/acssensors.4c00569 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 04.06.2024. Verfasst von Sathyan Babu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea. Hauptthemen laut MEDLINE: Ferrocyanides, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Research Foundation of Korea.
Abstract (Originalsprache)
Sensitive and/or multiplex electrochemical biosensors often require efficient (bio)catalytic conversion of substrates into insoluble electroactive products. The enzymatic formation and precipitation of coordination polymers under mild conditions offers a promising solution for this purpose. Herein, we report the enzymatic precipitation of Prussian blue (PB), a highly electroactive and ion-transporting coordination polymer, on an immunosensing electrode for application in a sensitive electrochemical immunosensor for detecting thyroid-stimulating hormone (TSH). Five pairs of redox enzymes and their specific reductants were examined to achieve rapid PB precipitation and electrochemical oxidation. Among these pairs, O2-insensitive flavin adenine dinucleotide-dependent glucose dehydrogenase (FAD-GDH) paired with glucose yielded the highest electrochemical signal-to-background (S/B) ratio. FAD-GDH catalyzed the conversion of Fe(CN)63- to Fe(CN)64-, which coordinated with Fe3+, leading to PB formation and subsequent precipitation through repeated conversions. The resulting PB precipitate, with its close proximity to the electrode, facilitated rapid electrochemical oxidation and generated a strong electrochemical signal. Notably, the precipitation and electrochemical oxidation of PB were more effective than those of its analogues. When applied to a sandwich-type immunosensor for TSH detection, the enzymatic PB precipitation achieved a calculated detection limit of approximately 2 pg/mL in artificial serum, covering the clinically relevant range. These findings indicate the potential widespread utility of PB precipitation and electrochemical oxidation for sensitive multiplex biomarker detection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea.
ORCID-Profile: Haesik Yang
Förderung
- National Research Foundation of Korea
Zitieren
APA
Babu, S., Lee, K., & Yang, H. (2024). Enzymatic Precipitation of Highly Electroactive and Ion-Transporting Prussian Blue for a Sensitive Electrochemical Immunosensor. ACS Sensors, 9(6), 3224-3232. https://doi.org/10.1021/acssensors.4c00569
Vancouver
Babu S, Lee K, Yang H. Enzymatic Precipitation of Highly Electroactive and Ion-Transporting Prussian Blue for a Sensitive Electrochemical Immunosensor. ACS Sensors. 2024;9(6):3224-3232. doi:10.1021/acssensors.4c00569
BibTeX
@article{Babu2024,
author = {Babu, Sathyan and Lee, Kyuseok and Yang, Haesik},
title = {Enzymatic Precipitation of Highly Electroactive and Ion-Transporting Prussian Blue for a Sensitive Electrochemical Immunosensor},
journal = {ACS Sensors},
year = {2024},
volume = {9},
number = {6},
pages = {3224--3232},
doi = {10.1021/acssensors.4c00569}
}
EUVIMED