Colorimetric Detection of Fentanyl Powder on Surfaces Using a Supramolecular Displacement Assay
ACS Sensors · 2024
DOI: 10.1021/acssensors.4c00517 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Andrea C Mora und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Tufts University, Medford, Massachusetts 02155, United States. Hauptthemen laut MEDLINE: Fentanyl, Colorimetry. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Army Contracting Command - Aberdeen Proving Ground.
Abstract (Originalsprache)
Fentanyl is a potent synthetic opioid with an alarmingly low lethal dosage of 2 mg. The equipment necessary to detect fentanyl in field settings (e.g., hand-held spectrometers) is restricted to highly trained, well-funded, and specialized personnel. Established point-of-need technologies, such as lateral flow immunochromatographic strips, are available; however, they often involve multiple contact-based steps (e.g., collection, mixing) that pose a higher risk to users handling unknown substances. Herein, we developed a colorimetric displacement assay capable of contactless detection of fentanyl in liquid or solid samples. The basis of our assay relies on the presence of fentanyl to displace a redox mediator, ferrocene carboxylic acid, inclusively bound in the cavity of a supramolecular host, CB[7]. The displacement is only possible in the presence of high affinity binding guests, like fentanyl (KA ∼ 106 M-1). The liberated redox guest can then react with indicator reagents that are free in solution, producing either: (i) a distinct blue color to indicate the presence of fentanyl or (ii) a pale blue tint in the absence of fentanyl. We demonstrate rapid and specific detection of fentanyl free base and fentanyl derivatives (e.g., acetyl fentanyl and furanyl fentanyl) against a panel of 9 other common drugs of abuse (e.g., morphine, cocaine, and heroin). Furthermore, we highlight the intended use of this assay by testing grains of fentanyl derivatives on a surface with a drop (i.e., 25 μL) of the assay reagent. We anticipate that this approach can be applied broadly to identify the presence of fentanyl at the point of need.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Tufts University, Medford, Massachusetts 02155, United States.
- Clear Scientific Inc, Cambridge, Massachusetts 02138, United States.
ORCID-Profile: Charles R Mace
Förderung
- Army Contracting Command - Aberdeen Proving Ground
Zitieren
APA
Mora, A. C., Vara, M., Reust, P., Code, A., Oliver, P., & Mace, C. R. (2024). Colorimetric Detection of Fentanyl Powder on Surfaces Using a Supramolecular Displacement Assay. ACS Sensors. https://doi.org/10.1021/acssensors.4c00517
Vancouver
Mora AC, Vara M, Reust P, Code A, Oliver P, Mace CR. Colorimetric Detection of Fentanyl Powder on Surfaces Using a Supramolecular Displacement Assay. ACS Sensors. 2024. doi:10.1021/acssensors.4c00517
BibTeX
@article{Mora2024,
author = {Mora, Andrea C and Vara, Madeline and Reust, Patrick and Code, Amanda and Oliver, Piercen and Mace, Charles R},
title = {Colorimetric Detection of Fentanyl Powder on Surfaces Using a Supramolecular Displacement Assay},
journal = {ACS Sensors},
year = {2024},
doi = {10.1021/acssensors.4c00517}
}