EUVIMEDEUVIMED entdecken
Crossref

Highly Sensitive Biomimetic Crack Pressure Sensor with Selective Frequency Response

Yan Li, Zongzheng Zhang iD, Songlin Du, Sicheng Zong, Zijun Ning, Fuling Yang

ACS Sensors · 2024

DOI: 10.1021/acssensors.4c00245 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Yan Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, China University of Mining and Technology─Beijing, Beijing 100083, China. Hauptthemen laut MEDLINE: Pressure, Hydrogels. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-sensitivity sensors in practical applications face the issue of environmental noise interference, requiring additional noise reduction circuits or filtering algorithms to improve the signal-to-noise ratio (SNR). To address this issue, this study proposes a biomimetic crack pressure sensor with selective frequency response based on hydrogel dampers. The core of this research is to construct a biomimetic crack pressure sensor with selective frequency response using the high-pass filtering characteristics of gelatin-chitosan hydrogels. This design, inspired by the slit sensilla and stratum corneum structure of spider legs, delves into the material properties and principles of hydrogel dampers, exploring their application in biomimetic crack pressure sensors, including parameter selection, structural design, and performance optimization. By delving into the nuanced characteristics and working principles of hydrogel dampers, their integration in biomimetic crack pressure sensors is examined, focusing on aspects like parameter selection, structural engineering, and performance enhancement to selectively sieve out low-frequency noise and transmit target vibrational signals. Experimental results demonstrate that this innovative sensor, while suppressing low-frequency vibration signals, can selectively detect high-frequency signals with high sensitivity. At different vibration frequencies, the relative change in resistance exceeds 200%, and the sensor sensitivity is 7 × 104 kPa-1. Furthermore, this sensor was applied to human voice detection, and the corresponding results verified its frequency-selective performance evidently. This study not only proposes a new design for pressure sensors but also offers fresh insights into the application of biomimetic crack pressure sensors in intricate environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PressureHydrogelsBiomimeticsBiomimetic MaterialsChitosanGelatinSignal-To-Noise RatioVibration

Stichwörter der Autor:innen

SNRbiomimetic crackfrequencyhydrogelpressure sensor

Substanzen

HydrogelsChitosanGelatin

Autor:innen und Institutionen

  • School of Mechanical and Electrical Engineering, China University of Mining and Technology─Beijing, Beijing 100083, China.

ORCID-Profile: Zongzheng Zhang

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Zhang, Z., Du, S., Zong, S., Ning, Z., & Yang, F. (2024). Highly Sensitive Biomimetic Crack Pressure Sensor with Selective Frequency Response. ACS Sensors. https://doi.org/10.1021/acssensors.4c00245

Vancouver

Li Y, Zhang Z, Du S, Zong S, Ning Z, Yang F. Highly Sensitive Biomimetic Crack Pressure Sensor with Selective Frequency Response. ACS Sensors. 2024. doi:10.1021/acssensors.4c00245

BibTeX
@article{Li2024,
  author = {Li, Yan and Zhang, Zongzheng and Du, Songlin and Zong, Sicheng and Ning, Zijun and Yang, Fuling},
  title = {Highly Sensitive Biomimetic Crack Pressure Sensor with Selective Frequency Response},
  journal = {ACS Sensors},
  year = {2024},
  doi = {10.1021/acssensors.4c00245}
}
Kostenlos starten →