Development and Characterization of Hemoglobin Microbubbles for Acoustic Blood Oxygen Level Dependent Imaging
ACS Sensors · 2024
DOI: 10.1021/acssensors.3c02349 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Sugandha Chaudhary und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75080, United States. Hauptthemen laut MEDLINE: Microbubbles, Oxygen, Hemoglobins, Ultrasonography. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, University of Texas at Dallas, National Institutes of Health.
Abstract (Originalsprache)
Oxygen levels in tissues and organs are crucial for their normal functioning, and approaches to monitor them non-invasively have wide biological and clinical applications. In this study, we developed a method of acoustically detecting oxygenation using contrast-enhanced ultrasound (CEUS) imaging. Our approach involved the use of specially designed hemoglobin-based microbubbles (HbMBs) that reversibly bind to oxygen and alter the state-dependent acoustic response. We confirmed that the bioactivity of hemoglobin remained intact after the microbubble shell was formed, and we did not observe any significant loss of heme. We conducted passive cavitation detection (PCD) experiments to confirm whether the acoustic properties of HbMBs vary based on the level of oxygen present. The experiments involved driving the HbMBs with a 1.1 MHz focused ultrasound transducer. Through the PCD data collected, we observed significant differences in the subharmonic and harmonic responses of the HbMBs when exposed to an oxygen-rich environment versus an oxygen-depleted one. We used a programmable ultrasound system to capture high-frame rate B mode videos of HbMBs in both oxy and deoxy conditions at the same time in a two-chambered flow phantom and observed that the mean pixel intensity of deoxygenated HbMB was greater than in the oxygenated state using B-mode imaging. Finally, we demonstrated that HbMBs can circulate in vivo and are detectable by a clinical ultrasound scanner. To summarize, our results indicate that CEUS imaging with HbMB has the potential to detect changes in tissue oxygenation and could be a valuable tool for clinical purposes in monitoring regional blood oxygen levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Bioengineering, The University of Texas at Dallas, Richardson, Texas 75080, United States.
- Department of Radiology, The Children's Hospital of Philadelphia, Philadelphia, Pennsylvania 19104, United States.
ORCID-Profile: Sugandha Chaudhary, Shashank R Sirsi
Förderung
- NCI NIH HHS
- University of Texas at Dallas
- National Institutes of Health
Zitieren
APA
Chaudhary, S., Akter, N., Pathour, T., Kian Pour, B., Rastegar, G., Menon, A., Brown, K. G., Fei, B., Hwang, M., & Sirsi, S. R. (2024). Development and Characterization of Hemoglobin Microbubbles for Acoustic Blood Oxygen Level Dependent Imaging. ACS Sensors. https://doi.org/10.1021/acssensors.3c02349
Vancouver
Chaudhary S, Akter N, Pathour T, Kian Pour B, Rastegar G, Menon A, et al. Development and Characterization of Hemoglobin Microbubbles for Acoustic Blood Oxygen Level Dependent Imaging. ACS Sensors. 2024. doi:10.1021/acssensors.3c02349
BibTeX
@article{Chaudhary2024,
author = {Chaudhary, Sugandha and Akter, Nasrin and Pathour, Teja and Kian Pour, Bahareh and Rastegar, Ghazal and Menon, Akshay and Brown, Katherine G and Fei, Baowei and Hwang, Misun and Sirsi, Shashank R},
title = {Development and Characterization of Hemoglobin Microbubbles for Acoustic Blood Oxygen Level Dependent Imaging},
journal = {ACS Sensors},
year = {2024},
doi = {10.1021/acssensors.3c02349}
}
EUVIMED