EUVIMEDEUVIMED entdecken
Crossref

Monolithic Integration of Ultraslim Flow Sensor and Medical Guidewire by Laser Filament Scanning Sintering for In Vivo Diagnostics of Cardiovascular Diseases

Myoung-Ock Cho iD, Sunyoung Kim, Seunghyun Back, Woojin Jang, Jin-Ho Choi, Bongchul Kang iD, Si-Hyung Lim

ACS Sensors · 2024

DOI: 10.1021/acssensors.3c01262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, 2024. Verfasst von Myoung-Ock Cho und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Systems Engineering, Graduate School, Kookmin University, Seoul 02707, Korea. Hauptthemen laut MEDLINE: Cardiovascular Diseases, Metal Nanoparticles. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 79 Literaturangaben. Gefördert von: Ministry of Health and Welfare, Ministry of Science and ICT, South Korea, National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, an ultraslim thermal flow sensor system integrated onto a 340 μm diameter medical guidewire was developed using a laser filament scanning sintering method for the early diagnosis of cardiovascular diseases. The proposed system is a calorimetric-based micro thermal flow sensor comprising a microheater and two thermistors. Prior to fabrication, the sensor design was optimized through flow simulation, and the patterned sensor was successfully implemented on a thin and curved surface of the medical guidewire using a laser patterning method with Ag nanoparticles. The performance of the ultraslim thermal flow sensor-on-guidewire system (SoW) was evaluated under pulsatile flow by using an artificial heartbeat simulator with differentially induced fluid flow velocities of up to 60 cm/s. The resulting electrical signals generated by the temperature difference between the two thermistors caused by the fluid flow were measured across different velocity ranges. Based on the obtained data, a calibration curve was derived to establish the relationship between the fluid velocity and the sensor output voltage. Furthermore, the SoW was tested on living animals, whereby the measured blood flow velocities were 60-90 cm/s in the left coronary artery of pigs. This research demonstrates the potential of ultraslim microsensors, such as the developed thermal flow sensor system, for various industries, particularly in the medical field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiovascular DiseasesMetal NanoparticlesAnimalsFemaleSwineSilverCalibrationLasers

Stichwörter der Autor:innen

blood flow ratecoronary arteryguidewirelaser filament scanning sinteringthermal flow sensor

Substanzen

Silver

Autor:innen und Institutionen

  • Department of Mechanical Systems Engineering, Graduate School, Kookmin University, Seoul 02707, Korea.
  • Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, 81, Irwonro, Gangnamgu, Seoul 06351, Republic of Korea.
  • Kookmin University, School of Mechanical Engineering, Kookmin University, Seoul 02707, Korea.

ORCID-Profile: Myoung-Ock Cho, Bongchul Kang

Förderung

  • Ministry of Health and Welfare
  • Ministry of Science and ICT, South Korea
  • National Research Foundation of Korea
  • Ministry of Trade, Industry and Energy

Zitieren

APA

Cho, M. O., Kim, S., Back, S., Jang, W., Choi, J. H., Kang, B., & Lim, S. H. (2024). Monolithic Integration of Ultraslim Flow Sensor and Medical Guidewire by Laser Filament Scanning Sintering for In Vivo Diagnostics of Cardiovascular Diseases. ACS Sensors. https://doi.org/10.1021/acssensors.3c01262

Vancouver

Cho MO, Kim S, Back S, Jang W, Choi JH, Kang B, et al. Monolithic Integration of Ultraslim Flow Sensor and Medical Guidewire by Laser Filament Scanning Sintering for In Vivo Diagnostics of Cardiovascular Diseases. ACS Sensors. 2024. doi:10.1021/acssensors.3c01262

BibTeX
@article{Cho2024,
  author = {Cho, Myoung-Ock and Kim, Sunyoung and Back, Seunghyun and Jang, Woojin and Choi, Jin-Ho and Kang, Bongchul and Lim, Si-Hyung},
  title = {Monolithic Integration of Ultraslim Flow Sensor and Medical Guidewire by Laser Filament Scanning Sintering for In Vivo Diagnostics of Cardiovascular Diseases},
  journal = {ACS Sensors},
  year = {2024},
  doi = {10.1021/acssensors.3c01262}
}
Kostenlos starten →