Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods

Xiaozhou Huang iD, Yaonian Li, Erin Witherspoon, Rui He, Greg Petruncio, Mikell Paige, Matthew Li, Tongchao Liu iD, Khalil Amine iD, Zhe Wang, Qiliang Li iD, Pei Dong iD

ACS Sensors · 22.09.2023 · 8 (9) · 3389-3399

DOI: 10.1021/acssensors.3c00578 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 17.08.2023. Verfasst von Xiaozhou Huang und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, George Mason University, Fairfax, Virginia 22030 United States. Hauptthemen laut MEDLINE: Volatile Organic Compounds, Ionic Liquids. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: U.S. Department of Energy, George Mason University Startup, NASA.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The detection of volatile organic compounds (VOCs) is an important topic for environmental safety and public health. However, the current commercial VOC detectors suffer from cross-sensitivity and low reproducibility. In this work, we present species-selective detection for VOCs using an electrochemical cell based on ionic liquid (IL) electrolytes with features of high selectivity and reliability. The voltammograms measured with the IL-based electrolyte absorbing different VOCs exhibited species-selective features that were extracted and classified by linear discriminant analysis (LDA). The detection system could identify as many as four types of VOCs, including methanol, ethanol, acetone, formaldehyde, and additional water. A mixture of methanol and formaldehyde was detected as well. The sample required for the VOCs classification system was 50 μL, or 1.164 mmol, on average. The response time for each VOC measurement is as fast as 24 s. The volume of VOCs such as formaldehyde in solution could also be quantified by LDA and electrochemical impedance spectroscopy techniques, respectively. The system showed a tunable detection range for 1.6 and 16% (w/v) CH2O solution by adjusting the composition of the electrolyte. The limit of detection was as low as 1 μL. For the 1.6% CH2O solution, the linearity calibration range was determined to be from 5.30 to 53.00 μmol with a limit of detection at 0.53 μmol. The mechanisms for VOCs determination and quantification are also thoroughly discussed. It is expected that this work could provide a new insight into the concept of electrochemical detection of VOCs with machine learning analysis and be applied to both VOCs gas monitoring and fluid detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Volatile Organic CompoundsIonic LiquidsReproducibility of ResultsMethanolAcetone

Stichwörter der Autor:innen

VOC detectionelectrochemistryfree radicalionic liquidlinear discriminant analysis

Substanzen

Volatile Organic CompoundsIonic LiquidsMethanolAcetone

Autor:innen und Institutionen

  • Department of Mechanical Engineering, George Mason University, Fairfax, Virginia 22030 United States.
  • Department of Chemistry & Biochemistry, George Mason University, Manassas, Virginia 20110, United States.
  • Department of Electrical and Computer Engineering, George Mason University, Fairfax, Virginia 22030 United States.
  • Department of Chemistry, Oakland University, Rochester Hills, Michigan 48309 United States.
  • Chemical Sciences and Engineering Division, Argonne National Laboratory, Argonne, Illinois 60439, United States.
  • Institute for Research and Medical Consultations (IRMC), Imam Abdulrahman Bin Faisal University (IAU), Dammam 34221, Saudi Arabia.

ORCID-Profile: Xiaozhou Huang, Tongchao Liu, Khalil Amine, Qiliang Li, Pei Dong

Förderung

  • U.S. Department of Energy
  • George Mason University Startup
  • NASA
  • Virginia Microelectronics Consortium (VMEC) Chair Professorship Grant

Zitieren

APA

Huang, X., Li, Y., Witherspoon, E., He, R., Petruncio, G., Paige, M., Li, M., Liu, T., Amine, K., Wang, Z., Li, Q., & Dong, P. (2023). Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods. ACS Sensors, 8(9), 3389-3399. https://doi.org/10.1021/acssensors.3c00578

Vancouver

Huang X, Li Y, Witherspoon E, He R, Petruncio G, Paige M, et al. Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods. ACS Sensors. 2023;8(9):3389-3399. doi:10.1021/acssensors.3c00578

BibTeX
@article{Huang2023,
  author = {Huang, Xiaozhou and Li, Yaonian and Witherspoon, Erin and He, Rui and Petruncio, Greg and Paige, Mikell and Li, Matthew and Liu, Tongchao and Amine, Khalil and Wang, Zhe and Li, Qiliang and Dong, Pei},
  title = {Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods},
  journal = {ACS Sensors},
  year = {2023},
  volume = {8},
  number = {9},
  pages = {3389--3399},
  doi = {10.1021/acssensors.3c00578}
}