EUVIMEDEUVIMED entdecken
Crossref

Polyethersulfone-Based Microfluidic Device Integrated with DNA Extraction on Paper and Recombinase Polymerase Amplification for the Detection of Salmonella enterica

Yunxuan Chen, Yaxi Hu iD, Xiaonan Lu iD

ACS Sensors · 23.06.2023 · 8 (6) · 2331-2339

DOI: 10.1021/acssensors.3c00387 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Sensors, online erschienen am 25.05.2023. Verfasst von Yunxuan Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Food, Nutrition and Health Program, Faculty of Land and Food Systems, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada. Hauptthemen laut MEDLINE: Salmonella enterica, Nucleic Acids. Die Arbeit wurde bisher 49-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canadian Produce Marketing Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rising consumption, large-scale production, and widespread distribution have been accompanied by an increase in the number of Salmonella infections reported to implicate contaminated food products. We developed a portable origami microfluidic device that enabled rapid detection of S. enterica from sample preparation to end-point detection, including nucleic acid extraction on paper dipstick without pipetting, nucleic acid amplification using isothermal recombinase polymerase amplification (RPA), and lateral flow assay for results readout. We also explored the feasibility of the polyethersulfone (PES) membrane as a new reaction matrix against the widely used chromatography paper to optimize nucleic acid amplification. Nucleic acid amplification was achieved within 20 min and demonstrated 100% specificity to S. enterica. The limit of detection of this PES-based microfluidic device was 260 CFU/mL and equivalent to RPA reaction in tube. A chromatography paper-based microfluidic device was found 1-log less in sensitivity for Salmonella detection compared to the use of PES. This PES-based microfluidic device could detect S. enterica in lettuce, chicken breast, and milk at concentrations of 6 CFU/g, 9 CFU/g, and 58 CFU/mL, respectively, after 6 h enrichment. PES has shown high compatibility to isothermal nucleic acid amplification and great potential to be implemented as an integrated sample-to-answer microfluidic device for the detection of pathogens in various food commodities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Salmonella entericaNucleic AcidsRecombinasesDNALab-On-A-Chip DevicesPolymersSulfones

Stichwörter der Autor:innen

DNA extractionSalmonellafood safetymicrofluidic “lab-on-a-chip”pathogenrecombinase polymerase amplification

Substanzen

RecombinasesNucleic AcidsDNApolyether sulfonePolymersSulfones

Autor:innen und Institutionen

  • Food, Nutrition and Health Program, Faculty of Land and Food Systems, The University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
  • Food Science Program, Department of Chemistry, Carleton University, 1125 Colonel By Drive, Ottawa, Ontario K1S 5B6, Canada.
  • Department of Food Science and Agricultural Chemistry, McGill University, 21111 Lakeshore Road,Sainte-Anne-de-Bellevue H9X 3V9 Quebec, Canada.

ORCID-Profile: Yaxi Hu, Xiaonan Lu

Förderung

  • Natural Sciences and Engineering Research Council of Canada
  • Canadian Produce Marketing Association

Zitieren

APA

Chen, Y., Hu, Y., & Lu, X. (2023). Polyethersulfone-Based Microfluidic Device Integrated with DNA Extraction on Paper and Recombinase Polymerase Amplification for the Detection of Salmonella enterica. ACS Sensors, 8(6), 2331-2339. https://doi.org/10.1021/acssensors.3c00387

Vancouver

Chen Y, Hu Y, Lu X. Polyethersulfone-Based Microfluidic Device Integrated with DNA Extraction on Paper and Recombinase Polymerase Amplification for the Detection of Salmonella enterica. ACS Sensors. 2023;8(6):2331-2339. doi:10.1021/acssensors.3c00387

BibTeX
@article{Chen2023,
  author = {Chen, Yunxuan and Hu, Yaxi and Lu, Xiaonan},
  title = {Polyethersulfone-Based Microfluidic Device Integrated with DNA Extraction on Paper and Recombinase Polymerase Amplification for the Detection of Salmonella enterica},
  journal = {ACS Sensors},
  year = {2023},
  volume = {8},
  number = {6},
  pages = {2331--2339},
  doi = {10.1021/acssensors.3c00387}
}
Kostenlos starten →