Bidirectional Phase Sensitivity in Holographic Phototransient Microscopy
ACS Photonics · 04.11.2026 · 13 (21) · 6460-6466
DOI: 10.1021/acsphotonics.6c01684 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Photonics, online erschienen am 15.10.2026. Verfasst von Emmanuel Kotu Robertson und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1100, Amsterdam 1081 HZ, The Netherlands. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission (Horizon Europe Framework Programme).
Abstract (Originalsprache)
Mid-infrared photothermal microscopy combines the chemical specificity of infrared absorption with the spatial resolution of visible light detection, but practical implementations face a persistent trade-off between forward-scattering (FWS) and backward-scattering (BWS) detection geometries. FWS provides quantitative, shape-independent phase contrast but requires two-sided optical access, which is difficult to achieve in aqueous or thick samples. BWS offers convenient single-sided access, but its signals are strongly distorted by depth-dependent interference for micrometer-scale objects. Here, we present a bidirectional femtosecond mid-infrared pump–probe holographic microscope capable of switching between FWS and BWS geometries within a single instrument and use it to introduce and validate a new imaging modality, internal forward scattering (IFS). IFS exploits the back reflection generated at the top surface of the mid-infrared-transparent sample substrate as an internally generated forward-scattering illumination wave, isolated from the directly backscattered field via temporal coherence gating. Using polystyrene beads on CaF2 substrates in air, water, and a refractive-index-matched glycerol–water mixture, we show that IFS reproduces the signal magnitudes and temporal dynamics of true FWS measurements while retaining the mechanical simplicity and single-sided accessibility of BWS. These results establish IFS as a practical, quantitative alternative to conventional FWS and BWS geometries for photothermal and, more broadly, quantitative phase imaging, with direct relevance to single-sided imaging of biological or solvent-contained specimens.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Physics and Astronomy, Vrije Universiteit Amsterdam, De Boelelaan 1100, Amsterdam 1081 HZ, The Netherlands.
ORCID-Profile: Emmanuel Kotu Robertson, Matz Liebel
Förderung
- European Commission (Horizon Europe Framework Programme)
Zitieren
APA
Robertson, E. K., van de Lockand, D., & Liebel, M. (2026). Bidirectional Phase Sensitivity in Holographic Phototransient Microscopy. ACS Photonics, 13(21), 6460-6466. https://doi.org/10.1021/acsphotonics.6c01684
Vancouver
Robertson EK, van de Lockand D, Liebel M. Bidirectional Phase Sensitivity in Holographic Phototransient Microscopy. ACS Photonics. 2026;13(21):6460-6466. doi:10.1021/acsphotonics.6c01684
BibTeX
@article{Robertson2026,
author = {Robertson, Emmanuel Kotu and van de Lockand, Dennis and Liebel, Matz},
title = {Bidirectional Phase Sensitivity in Holographic Phototransient Microscopy},
journal = {ACS Photonics},
year = {2026},
volume = {13},
number = {21},
pages = {6460--6466},
doi = {10.1021/acsphotonics.6c01684}
}
EUVIMED