EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Benchmarking Reconstructive Spectrometer with Multiresonant Cavities

Chunhui Yao iD, Kangning Xu, Tianhua Lin, Jie Ma, Chumeng Yao, Peng Bao, Zhitian Shi, Richard Penty, Qixiang Cheng

ACS Photonics · 18.09.2024 · 11 (9) · 3730-3740

DOI: 10.1021/acsphotonics.4c00915 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Photonics, online erschienen am 15.08.2024. Verfasst von Chunhui Yao und 8 weiteren Autor:innen. Beteiligte Einrichtung: Centre for Photonic Systems, Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, U.K. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Engineering and Physical Sciences Research Council, China Scholarship Council.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Recent years have seen the rapid development of miniaturized reconstructive spectrometers (RSs), yet they still confront a range of technical challenges, such as bandwidth/resolution ratio, sensing speed, and/or power efficiency. Reported RS designs often suffer from insufficient decorrelation between sampling channels, which, in essence, is due to inadequate engineering of sampling responses. This in turn results in poor spectral-pixel-to-channel ratios (SPCRs), typically restricted at single digits. So far, there lacks a general guideline for manipulating RS sampling responses for the effectiveness of spectral information acquisition. In this study, we shed light on a fundamental parameter from the compressive sensing (CS) theory-the average mutual correlation coefficient ν-and provide insight into how it serves as a critical benchmark in RS design. To this end, we propose a novel RS design with multiresonant cavities, consisting of a series of partial reflective interfaces. Such multicavity configuration allows the superlative optimization of sampling matrices to achieve minimized ν. Experimentally, we implement a single-shot, dual-band RS on a SiN platform, realizing an overall operation bandwidth of 270 nm and a

Autor:innen und Institutionen

  • Centre for Photonic Systems, Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, U.K.
  • GlitterinTech Limited, Xuzhou 221000, China.

ORCID-Profile: Chunhui Yao

Förderung

  • Engineering and Physical Sciences Research Council
  • China Scholarship Council

Zitieren

APA

Yao, C., Xu, K., Lin, T., Ma, J., Yao, C., Bao, P., Shi, Z., Penty, R., & Cheng, Q. (2024). Benchmarking Reconstructive Spectrometer with Multiresonant Cavities. ACS Photonics, 11(9), 3730-3740. https://doi.org/10.1021/acsphotonics.4c00915

Vancouver

Yao C, Xu K, Lin T, Ma J, Yao C, Bao P, et al. Benchmarking Reconstructive Spectrometer with Multiresonant Cavities. ACS Photonics. 2024;11(9):3730-3740. doi:10.1021/acsphotonics.4c00915

BibTeX
@article{Yao2024,
  author = {Yao, Chunhui and Xu, Kangning and Lin, Tianhua and Ma, Jie and Yao, Chumeng and Bao, Peng and Shi, Zhitian and Penty, Richard and Cheng, Qixiang},
  title = {Benchmarking Reconstructive Spectrometer with Multiresonant Cavities},
  journal = {ACS Photonics},
  year = {2024},
  volume = {11},
  number = {9},
  pages = {3730--3740},
  doi = {10.1021/acsphotonics.4c00915}
}
Kostenlos starten →