EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport

N Muralikrishna, Sayan Das, Somnath Santra, Parikshit Sahatiya, Arnab Guha

ACS Omega · 17.11.2026

DOI: 10.1021/acsomega.6c12419 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 17.11.2026. Verfasst von N Muralikrishna und 4 weiteren Autor:innen. Die Arbeit nennt 86 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Anusandhan National Research Foundation, Department of Science and Technology, Ministry of Science and Technology, India, Birla Institute of Technology and Science, Pilani.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The combined effect of geometric obstruction and auxiliary inlet on sensor response time for a microfluidics-integrated biosensor has been numerically investigated in this study. The flow behavior and mass transfer of an analyte have been modeled using incompressible Navier–Stokes equations coupled with convection–diffusion and Langmuir adsorption kinetics equations for comparable time scales of diffusion and surface reaction. Introduction of a block increases the analyte velocity near the sensor surface with subsequent reduction in diffusion boundary layer thickness, thereby ameliorating the sensor response time. Insertion of an auxiliary inlet diminishes the sensor response time to a greater extent by confining a thin layer of analyte above the sensor surface. A systematic parametric study is conducted to evaluate the blended effects of block height, block position, block width, auxiliary inlet position, and auxiliary inlet velocity on sensor performance. Taguchi-based optimization techniques employing an L27 orthogonal array alongside signal-to-noise ratio analysis and analysis of variance have been utilized for identification of optimal parameter combinations. The results indicate that the auxiliary inlet velocity is the most influential parameter with a contribution of 65.8% toward the decrement in sensor response time. The findings demonstrate that the combination of block-induced flow-field modifications and auxiliary-inlet-mediated flow confinement effect significantly augments analyte transport to the sensor surface, thereby decreasing the sensor response time by approximately 92% in comparison to the scenario devoid of a block and auxiliary inlet. This study provides valuable insights for the design and optimization of point-of-care microfluidic devices with reduced detection time.

Förderung

  • Anusandhan National Research Foundation
  • Department of Science and Technology, Ministry of Science and Technology, India
  • Birla Institute of Technology and Science, Pilani

Zitieren

APA

Muralikrishna, N., Das, S., Santra, S., Sahatiya, P., & Guha, A. (2026). Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport. ACS Omega. https://doi.org/10.1021/acsomega.6c12419

Vancouver

Muralikrishna N, Das S, Santra S, Sahatiya P, Guha A. Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport. ACS Omega. 2026. doi:10.1021/acsomega.6c12419

BibTeX
@article{Muralikrishna2026,
  author = {Muralikrishna, N and Das, Sayan and Santra, Somnath and Sahatiya, Parikshit and Guha, Arnab},
  title = {Optimization of Sensor Response Time in Microfluidics-Based Biosensors with Balanced Analyte Transport},
  journal = {ACS Omega},
  year = {2026},
  doi = {10.1021/acsomega.6c12419}
}
Kostenlos starten →