EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Laser-Reduced Graphene Oxide Electrodes as a Self-Stabilizing Scaffold for Neat Ionic Liquids in Humidity Sensing

Stefanos Matsalis, Dionysios Vroulias, Nikos Koutroumanis, George Paterakis, Labrini Sygellou, Vassilios Dracopoulos, Theophilos Ioannides, Costas Galiotis

ACS Omega · 18.11.2026

DOI: 10.1021/acsomega.6c11279 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 18.11.2026. Verfasst von Stefanos Matsalis und 7 weiteren Autor:innen. Die Arbeit nennt 77 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ionic liquids (ILs) are attractive sensing materials for humidity detection because of their hydrophilicity and their highly tunable physicochemical properties. However, most reported IL-based humidity sensors require an additional immobilization matrix, such as a polymer, nanoparticle composite, or poly(ionic liquid), to stabilize the liquid phase on solid-state electrodes, thereby increasing fabrication complexity. Here, we report capacitive humidity sensors based on neat 1-hexyl-1-methyl-2-(3-pyridinyl)pyrrolidinium methanesulfonate ([HexNic][MeSO3]) directly immobilized within porous laser-reduced graphene oxide (LRGO) interdigitated electrodes. Graphene oxide (GO) was laser-reduced using a CO2 laser to produce a highly porous LRGO structure containing 92 atom % C and 8 atom % O. The IL was subsequently drop-cast onto the electrodes and retained within the porous LRGO network without the need for an additional immobilization matrix. At the optimal IL loading, the resulting sensors exhibited a sensitivity of 1650 pF/% RH, with response and recovery times of 180 and 33 s, respectively. The devices also showed very low hysteresis, with a maximum value of 1.01% RH and stable capacitive performance over 30 days. The humidity-sensing mechanism was elucidated by using complex impedance spectroscopy and attenuated total reflectance-Fourier transform infrared spectroscopy (FTIR-ATR). As a proof of concept, the sensor was further applied to respiratory monitoring and successfully distinguished between slow- and fast-breathing patterns. To the best of our knowledge, this is the first demonstration of a neat IL directly immobilized within a porous graphene-based electrode for capacitive humidity sensing without an additional polymeric or composite matrix. The approach provides a simple and scalable route to high-performance IL-based humidity sensors.

Zitieren

APA

Matsalis, S., Vroulias, D., Koutroumanis, N., Paterakis, G., Sygellou, L., Dracopoulos, V., Ioannides, T., & Galiotis, C. (2026). Laser-Reduced Graphene Oxide Electrodes as a Self-Stabilizing Scaffold for Neat Ionic Liquids in Humidity Sensing. ACS Omega. https://doi.org/10.1021/acsomega.6c11279

Vancouver

Matsalis S, Vroulias D, Koutroumanis N, Paterakis G, Sygellou L, Dracopoulos V, et al. Laser-Reduced Graphene Oxide Electrodes as a Self-Stabilizing Scaffold for Neat Ionic Liquids in Humidity Sensing. ACS Omega. 2026. doi:10.1021/acsomega.6c11279

BibTeX
@article{Matsalis2026,
  author = {Matsalis, Stefanos and Vroulias, Dionysios and Koutroumanis, Nikos and Paterakis, George and Sygellou, Labrini and Dracopoulos, Vassilios and Ioannides, Theophilos and Galiotis, Costas},
  title = {Laser-Reduced Graphene Oxide Electrodes as a Self-Stabilizing Scaffold for Neat Ionic Liquids in Humidity Sensing},
  journal = {ACS Omega},
  year = {2026},
  doi = {10.1021/acsomega.6c11279}
}
Kostenlos starten →