Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose
ACS Omega · 10.11.2026 · 11 (44) · 69117-69126
DOI: 10.1021/acsomega.6c09156 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Omega, online erschienen am 24.10.2026. Verfasst von Che-Liang Yeh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Chemistry, Academia Sinica, Nankang, Taipei 11529, Taiwan. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Academia Sinica, National Science and Technology Council.
Abstract (Originalsprache)
Microfluidic paper-based analytical devices (μPADs) provide an attractive platform for diagnostics owing to their low cost, passive fluid transport, and ease of fabrication. However, integrating dual-sensing capabilities into a single paper device while maintaining a simple manufacturing process remains challenging. Here, we present a foldable dual-mode microfluidic paper-based analytical device (DM-μPAD) that integrates laser-induced graphene (LIG)-based electrochemical sensing with enzyme-mediated colorimetric detection. A straightforward laser-patterning strategy was used to fabricate LIG electrodes directly patterned onto the polyimide tape-covered cellulose paper via a one-step laser engraving process, forming a conductive graphene network that serves as an electrochemical sensing module. A screen-printing process was used to form hydrophobic perfluoropolyether barriers, which define capillary-driven microfluidic channels that guide sample transport between sensing regions. The folded architecture enhances fluid-electrode interaction and enables simultaneous electrochemical and colorimetric measurements within a single analytical platform without electrode transfer or complex assembly. This dual-readout technique provides cross-validation of results to enhance detection reliability. The proposed DM-μPAD demonstrated good selectivity against common nonspecific compounds, a wide linear detection range of 0.01 to 3.0 mM, and a low detection limit of 9.23 μM in the electrochemical mode, while displaying a dynamic detection range of 0.1 to 2.0 mM with a detection limit of 57.9 μM in the colorimetric mode. Furthermore, the platform maintained high reproducibility, mechanical flexibility, and environmental stability. This work highlights the potential of laser-induced graphene-based paper microfluidics as a versatile platform for developing portable, cost-effective, and multiplexed biosensing devices.
Autor:innen und Institutionen
- Institute of Chemistry, Academia Sinica, Nankang, Taipei 11529, Taiwan.
ORCID-Profile: Syed Atif Ali, Hsiung-Lin Tu
Förderung
- Academia Sinica
- National Science and Technology Council
Zitieren
APA
Yeh, C. L., Ali, S. A., Wu, W. T., & Tu, H. L. (2026). Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose. ACS Omega, 11(44), 69117-69126. https://doi.org/10.1021/acsomega.6c09156
Vancouver
Yeh CL, Ali SA, Wu WT, Tu HL. Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose. ACS Omega. 2026;11(44):69117-69126. doi:10.1021/acsomega.6c09156
BibTeX
@article{Yeh2026,
author = {Yeh, Che-Liang and Ali, Syed Atif and Wu, Wen-Ti and Tu, Hsiung-Lin},
title = {Laser-Induced Graphene Paper-Based Microfluidic Platform for Dual-Mode Electrochemical and Colorimetric Detection of Glucose},
journal = {ACS Omega},
year = {2026},
volume = {11},
number = {44},
pages = {69117--69126},
doi = {10.1021/acsomega.6c09156}
}
EUVIMED