Processing-Tuned Laser-Induced Graphene Transducers for Polyaniline pH Sensors
ACS Omega · 10.11.2026 · 11 (44) · 69061-69076
DOI: 10.1021/acsomega.6c09091 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Omega, online erschienen am 27.10.2026. Verfasst von Atik Saha und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, Missouri 65409, United States. Die Arbeit nennt 82 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology.
Abstract (Originalsprache)
Flexible pH sensors are important for wearable, biomedical, environmental, and process-monitoring applications, but achieving simple, scalable fabrication while maintaining high sensing performance remains challenging. Laser-induced graphene (LIG) has emerged as a promising transducer material because it enables direct laser patterning of porous, conductive graphitized carbon electrodes on flexible substrates. Although laser-processing conditions are known to affect LIG morphology, graphitization, and electrical properties, their influence on pH-sensitive layer formation and pH-sensing performance has not been systematically investigated. In this study, polyaniline (PANi)-modified LIG pH sensors were fabricated using four laser-processing combinations of laser power and scan speed. The resulting LIG and PANi/LIG electrodes were characterized using sheet-resistance measurements, optical microscopy, SEM, Raman spectroscopy, and XPS. PANi was electropolymerized on the LIG working electrodes under identical cyclic voltammetry conditions, and the assembled sensors were evaluated in pH 4–9 buffer solutions. The results showed that laser processing produced distinct LIG morphologies, porosities, sheet resistance, and PANi coverage, leading to different sensing performances. Among the samples, PANi/LIG-9.2–350, fabricated at 9.2 W and 350 mm/s, exhibited the best overall performance, with a near-Nernstian sensitivity of −60.04 mV/pH, a 12 h drift rate of 1.67 mV/h, hysteresis of 2.06 mV, and rapid response time of 13.2 s. These findings emphasize the significance of laser-processing-dependent LIG microstructure and electrical properties in governing PANi deposition behavior and resulting potentiometric pH-sensing performance.
Autor:innen und Institutionen
- Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology, Rolla, Missouri 65409, United States.
ORCID-Profile: Bo Mi Lee
Förderung
- Department of Mechanical and Aerospace Engineering, Missouri University of Science and Technology
Zitieren
APA
Saha, A., & Lee, B. M. (2026). Processing-Tuned Laser-Induced Graphene Transducers for Polyaniline pH Sensors. ACS Omega, 11(44), 69061-69076. https://doi.org/10.1021/acsomega.6c09091
Vancouver
Saha A, Lee BM. Processing-Tuned Laser-Induced Graphene Transducers for Polyaniline pH Sensors. ACS Omega. 2026;11(44):69061-69076. doi:10.1021/acsomega.6c09091
BibTeX
@article{Saha2026,
author = {Saha, Atik and Lee, Bo Mi},
title = {Processing-Tuned Laser-Induced Graphene Transducers for Polyaniline pH Sensors},
journal = {ACS Omega},
year = {2026},
volume = {11},
number = {44},
pages = {69061--69076},
doi = {10.1021/acsomega.6c09091}
}
EUVIMED