EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of cVSSI-Based Direct-Infusion DIA-MS for Rapid Monoclonal Antibody Peptide Mapping

Herbi Yuliantoro, Olanrewaju Awoyemi, Amanda Overby, Stephen J. Valentine, Peng Li

ACS Omega · 23.11.2026

DOI: 10.1021/acsomega.6c07989 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 23.11.2026. Verfasst von Herbi Yuliantoro und 4 weiteren Autor:innen. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Division of Chemistry, National Institute of General Medical Sciences.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Liquid chromatography coupled with mass spectrometry is widely used for monoclonal antibody peptide mapping, but chromatographic separation increases the analysis time and limits sample throughput. Direct infusion mass spectrometry provides a faster alternative, although peptide detection can be limited by ion suppression, spectral complexity, and reduced reproducibility in the absence of chromatographic separation. Here, we evaluated capillary vibrating sharp-edge spray ionization coupled with direct-infusion data-independent acquisition mass spectrometry (cVSSI-DI-DIA-MS) for rapid peptide mapping and modification detection of the NIST monoclonal antibody reference material. cVSSI was compared with conventional electrospray ionization under different solvent compositions and reduced sample amount conditions. Under optimized direct-infusion DIA conditions, cVSSI provided high sequence coverage of the antibody heavy and light chains within approximately 7.8 min of acquisition. Compared with ESI, cVSSI showed more consistent peptide coverage under aqueous and ammonium hydroxide solvent conditions and maintained improved peptide detection after a 10-fold dilution. The workflow also enabled the detection of selected modified peptides. Three oxidized peptides met the fragment-ion detection criteria, and oxidation was localized to Met255. One deamidated peptide was observed at the MS1 precursor level with a tentative fragment ion support. Relative levels were estimated from MS1 precursor areas for this deamidated form and for the oxidized DTLMISR. Finally, a targeted DIA strategy reduced the acquisition time to approximately 1.4 min while retaining reproducible antibody sequence coverage. Future work will focus on further improving the performance of the cVSSI-based method to achieve reliable quantitation of most modifications, differentiation of aspartate isomerization, and optimal sequence coverage that meets the needs for biotherapeutic applications.

Förderung

  • Division of Chemistry
  • National Institute of General Medical Sciences

Zitieren

APA

Yuliantoro, H., Awoyemi, O., Overby, A., Valentine, S. J., & Li, P. (2026). Evaluation of cVSSI-Based Direct-Infusion DIA-MS for Rapid Monoclonal Antibody Peptide Mapping. ACS Omega. https://doi.org/10.1021/acsomega.6c07989

Vancouver

Yuliantoro H, Awoyemi O, Overby A, Valentine SJ, Li P. Evaluation of cVSSI-Based Direct-Infusion DIA-MS for Rapid Monoclonal Antibody Peptide Mapping. ACS Omega. 2026. doi:10.1021/acsomega.6c07989

BibTeX
@article{Yuliantoro2026,
  author = {Yuliantoro, Herbi and Awoyemi, Olanrewaju and Overby, Amanda and Valentine, Stephen J. and Li, Peng},
  title = {Evaluation of cVSSI-Based Direct-Infusion DIA-MS for Rapid Monoclonal Antibody Peptide Mapping},
  journal = {ACS Omega},
  year = {2026},
  doi = {10.1021/acsomega.6c07989}
}
Kostenlos starten →