Influence of Operating Conditions and Cell Design on the Performance of Low-Temperature Direct Ammonia Fuel Cells
ACS Omega · 11.08.2026 · 11 (31) · 46524-46535
DOI: 10.1021/acsomega.6c04131 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Omega, online erschienen am 28.07.2026. Verfasst von Daniela S Falcão und 5 weiteren Autor:innen. Beteiligte Einrichtung: CEFT, ALiCE, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, Porto 4200-465, Portugal. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Funda??o para a Ci?ncia e a Tecnologia, Funda??o Calouste Gulbenkian.
Abstract (Originalsprache)
This work investigates the effect of operating and cell design parameters on the performance of a low-temperature direct ammonia fuel cell (DAFC), employing an anion exchange membrane (AEM). The effects of temperature, ammonia and KOH concentrations, reactant flow rates, and air humidity are evaluated in a 5 cm2 DAFC. Temperature is identified as the most influential operating condition, with higher values enhancing electrochemical kinetics and membrane conductivity. Increased concentrations of both ammonia and potassium hydroxide solutions also tend to have a beneficial effect. The highest performance is achieved at 5 M NH4OH and 2 M KOH. Variations in feeding solution and air flow rates have a relatively small effect on the performance. At 40 °C, the relative humidity of the air (RHair) has no effect on the DAFC performance. At 60 °C, decreasing RHair from 100% to 75% increases performance, but no further benefit is observed with RHair of 50%. Among the membranes tested, FAS-30 exhibits the best performance, whereas Sustainion X37-50 grade RT performance is limited by high ammonia permeability. Although not directly compared, results indicate that bimetallic PtIr/C catalysts outperform Pt-based catalysts in the anode. Increasing the loading of the Pt and PtIr/C catalysts improves the activity of the electrode. Using PtIr/C electrodes in combination with a FAA-3-PK-130 membrane yields a peak power density of 12.2 mW·cm–2 at 80 °C. This study provides valuable insights into the operation and design of DAFCs, thereby contributing to the limited data currently available on this type of fuel cell.
Autor:innen und Institutionen
- CEFT, ALiCE, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, Porto 4200-465, Portugal.
- LSRE-LCM, ALiCE, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, Porto 4200-465, Portugal.
ORCID-Profile: Daniela S Falcão, Diogo F M Santos, Cláudia G Silva
Förderung
- Funda??o para a Ci?ncia e a Tecnologia
- Funda??o Calouste Gulbenkian
Zitieren
APA
Falcão, D. S., Jorge, M. G. S., Santos, D. F. M., Silva, C. G., Pinto, A. M. F. R., & Ferreira, R. B. (2026). Influence of Operating Conditions and Cell Design on the Performance of Low-Temperature Direct Ammonia Fuel Cells. ACS Omega, 11(31), 46524-46535. https://doi.org/10.1021/acsomega.6c04131
Vancouver
Falcão DS, Jorge MGS, Santos DFM, Silva CG, Pinto AMFR, Ferreira RB. Influence of Operating Conditions and Cell Design on the Performance of Low-Temperature Direct Ammonia Fuel Cells. ACS Omega. 2026;11(31):46524-46535. doi:10.1021/acsomega.6c04131
BibTeX
@article{Falco2026,
author = {Falcão, Daniela S and Jorge, Margarida G S and Santos, Diogo F M and Silva, Cláudia G and Pinto, Alexandra M F R and Ferreira, Rui B},
title = {Influence of Operating Conditions and Cell Design on the Performance of Low-Temperature Direct Ammonia Fuel Cells},
journal = {ACS Omega},
year = {2026},
volume = {11},
number = {31},
pages = {46524--46535},
doi = {10.1021/acsomega.6c04131}
}
EUVIMED