EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Sensitive Methanol and Formaldehyde Detection in Enzyme Assays Shows Applicability to Diverse Sample Matrices

Michael Schmidt Madsen, Cecilie Nørskov Jensen, Jane Wittrup Agger iD

ACS Omega · 28.07.2026 · 11 (29) · 43526-43539

DOI: 10.1021/acsomega.6c02236 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 15.07.2026. Verfasst von Michael Schmidt Madsen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology and Biomedicine, Technical University of Denmark, Søltofts Plads 221, Kongens Lyngby 2800, Denmark. Die Arbeit nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Danmarks Tekniske Universitet, Novo Nordisk Fonden, University of Queensland.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Formaldehyde and methanol are important compounds in enzymatic reactions, food products, and biological processes. However, sensitive and accurate detection of these compounds remains a critical challenge. The chromotropic acid method can detect formaldehyde and methanol after prior oxidation via formation of a purple chromogen, which is formed when chromotropic acid reacts with formaldehyde in sulfuric acid. The method allows fast analysis within a few minutes and enables accurate quantification of formaldehyde down to low micromolar concentrations. The addition of sodium bisulfite can further enhance the sensitivity of the method by stabilizing formaldehyde. Although the method is highly sensitive and specific for formaldehyde detection, it is not routinely applied in enzyme assay analysis. We demonstrate that the chromotropic acid method is suitable for sensitive quantification of formaldehyde and methanol through oxidation to formaldehyde (catalyzed by alcohol oxidase) in two enzyme assays comprising methanol dehydrogenase and glucuronoyl esterase. Most importantly, we show how the method can be tailored to variable experimental conditions, potentially enabling detection in various sample matrices. We successfully implemented the method for versatile, fast, and sensitive detection of both methanol and formaldehyde.

Autor:innen und Institutionen

  • Department of Biotechnology and Biomedicine, Technical University of Denmark, Søltofts Plads 221, Kongens Lyngby 2800, Denmark.

ORCID-Profile: Jane Wittrup Agger

Förderung

  • Danmarks Tekniske Universitet
  • Novo Nordisk Fonden
  • University of Queensland

Zitieren

APA

Schmidt Madsen, M., Nørskov Jensen, C., & Wittrup Agger, J. (2026). Sensitive Methanol and Formaldehyde Detection in Enzyme Assays Shows Applicability to Diverse Sample Matrices. ACS Omega, 11(29), 43526-43539. https://doi.org/10.1021/acsomega.6c02236

Vancouver

Schmidt Madsen M, Nørskov Jensen C, Wittrup Agger J. Sensitive Methanol and Formaldehyde Detection in Enzyme Assays Shows Applicability to Diverse Sample Matrices. ACS Omega. 2026;11(29):43526-43539. doi:10.1021/acsomega.6c02236

BibTeX
@article{SchmidtMadsen2026,
  author = {Schmidt Madsen, Michael and Nørskov Jensen, Cecilie and Wittrup Agger, Jane},
  title = {Sensitive Methanol and Formaldehyde Detection in Enzyme Assays Shows Applicability to Diverse Sample Matrices},
  journal = {ACS Omega},
  year = {2026},
  volume = {11},
  number = {29},
  pages = {43526--43539},
  doi = {10.1021/acsomega.6c02236}
}
Kostenlos starten →