EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Practical Approach to Efficiency Calibration of an HPGe Gamma-Ray Spectrometer for Soil Matrix Measurements Using Reference Materials

Deniz Agehan Kahraman, Ayse Nur Esen, Erdi Sirin

ACS Omega · 21.11.2026

DOI: 10.1021/acsomega.6c02183 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 21.11.2026. Verfasst von Deniz Agehan Kahraman und 2 weiteren Autor:innen. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Türkiye Bilimsel ve Teknolojik Arastirma Kurumu.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, a metrologically traceable and cost-effective efficiency calibration method for a coaxial HPGe gamma-ray spectrometer was developed using the IAEA–312 soil reference material and validated with the IAEA–447 moss-soil reference material. The efficiency curve was derived from selected gamma-ray lines of 214Pb and 214Bi in the energy range 242–1764 keV and fitted using a fourth-order logarithmic polynomial. The fitted model showed excellent agreement with the experimental data (R2 ≈ 0.996), with residuals within ±6%. The calibration was applied to determine the activity concentrations of 226Ra, 232Th, 137Cs, and 40K in IAEA–447. The measured values were in good agreement with the certified values, with relative deviations below 6% and all zeta-scores well below unity, indicating no statistically significant bias and confirming the traceability of the efficiency transfer. A comprehensive uncertainty analysis showed that the uncertainty in the efficiency calibration primarily determines overall accuracy, whereas counting statistics dominate for weaker gamma-ray lines. The results demonstrated that this approach provides a practical, matrix-matched calibration in which geometry-specific effects are inherently accounted for through empirical transfer and verified by reference material validation.

Förderung

  • Türkiye Bilimsel ve Teknolojik Arastirma Kurumu

Zitieren

APA

Kahraman, D. A., Esen, A. N., & Sirin, E. (2026). A Practical Approach to Efficiency Calibration of an HPGe Gamma-Ray Spectrometer for Soil Matrix Measurements Using Reference Materials. ACS Omega. https://doi.org/10.1021/acsomega.6c02183

Vancouver

Kahraman DA, Esen AN, Sirin E. A Practical Approach to Efficiency Calibration of an HPGe Gamma-Ray Spectrometer for Soil Matrix Measurements Using Reference Materials. ACS Omega. 2026. doi:10.1021/acsomega.6c02183

BibTeX
@article{Kahraman2026,
  author = {Kahraman, Deniz Agehan and Esen, Ayse Nur and Sirin, Erdi},
  title = {A Practical Approach to Efficiency Calibration of an HPGe Gamma-Ray Spectrometer for Soil Matrix Measurements Using Reference Materials},
  journal = {ACS Omega},
  year = {2026},
  doi = {10.1021/acsomega.6c02183}
}
Kostenlos starten →