EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Flexible PANI–PVDF Composite Membrane Ammonia Sensor for Chilled Meat Freshness Monitoring

Yulong Sun iD, Weiguo Lin iD

ACS Omega · 11.11.2025 · 10 (44) · 52921-52930

DOI: 10.1021/acsomega.5c06865 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 27.10.2025. Verfasst von Yulong Sun und 1 weiteren Autor:innen. Beteiligte Einrichtung: College of Engineering, Huazhong Agricultural University, Wuhan 430070, China. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Fundamental Research Funds for the Central Universities, Hubei Provincial Key Research and Development Program.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the increasing demand for food safety and quality monitoring, efficient freshness detection technologies are crucial. This study presents a flexible ammonia sensor based on polyaniline (PANI)-poly-(vinylidene fluoride) (PVDF) composite membrane integrated with silver electrodes for rapid chilled meat freshness assessment. A uniform PANI-sensitive layer was synthesized on the PVDF membrane via chemical polymerization, followed by screen-printing of highly conductive silver interdigitated electrodes. Leveraging PANI's high sensitivity to NH3, the sensor enables real-time monitoring of ammonia released during meat storage, thus indirectly reflecting meat freshness. Experimental results demonstrate that the sensor exhibits excellent sensitivity (response >20% at 10 ppm of NH3) and rapid response dynamics (T 90 ≈ 240 s at 10 ppm of NH3). By establishing correlations among sensor response, total volatile basic nitrogen (TVB-N) content, and storage time, an accurate freshness evaluation of chilled meat is achieved. Its simple fabrication, low cost, and easy integration provide an efficient and reliable technical solution for food freshness monitoring.

Autor:innen und Institutionen

  • College of Engineering, Huazhong Agricultural University, Wuhan 430070, China.

ORCID-Profile: Yulong Sun, Weiguo Lin

Förderung

  • Fundamental Research Funds for the Central Universities
  • Hubei Provincial Key Research and Development Program

Zitieren

APA

Sun, Y., & Lin, W. (2025). Flexible PANI–PVDF Composite Membrane Ammonia Sensor for Chilled Meat Freshness Monitoring. ACS Omega, 10(44), 52921-52930. https://doi.org/10.1021/acsomega.5c06865

Vancouver

Sun Y, Lin W. Flexible PANI–PVDF Composite Membrane Ammonia Sensor for Chilled Meat Freshness Monitoring. ACS Omega. 2025;10(44):52921-52930. doi:10.1021/acsomega.5c06865

BibTeX
@article{Sun2025,
  author = {Sun, Yulong and Lin, Weiguo},
  title = {Flexible PANI–PVDF Composite Membrane Ammonia Sensor for Chilled Meat Freshness Monitoring},
  journal = {ACS Omega},
  year = {2025},
  volume = {10},
  number = {44},
  pages = {52921--52930},
  doi = {10.1021/acsomega.5c06865}
}
Kostenlos starten →