EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Thomas Serrano iD, Alyssa F Espley, Savannah M Potter, Kenneth A Ross, PoKi Tse iD, Nathan P Bessen iD, Heather M Felmy iD, Hope E Lackey, Jarrod R Allred, Brienne N Seiner iD, Gregg J Lumetta iD, Gilbert L Nelson und 2 weitere

ACS Omega · 30.04.2025

DOI: 10.1021/acsomega.4c07963 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 30.04.2025. Verfasst von Thomas Serrano und 13 weiteren Autor:innen. Beteiligte Einrichtung: Pacific Northwest National Laboratory, Richland, Washington 99352, United States. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Nuclear Security Administration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

Autor:innen und Institutionen

  • Pacific Northwest National Laboratory, Richland, Washington 99352, United States.
  • Department of Chemistry, Washington State University, Pullman, Washington 99164, United States.
  • Department of Chemistry, The College of Idaho, Caldwell, Idaho 83605, United States.

ORCID-Profile: Thomas Serrano, PoKi Tse, Nathan P Bessen, Heather M Felmy, Brienne N Seiner, Gregg J Lumetta, Samuel A Bryan

Förderung

  • National Nuclear Security Administration

Zitieren

APA

Serrano, T., Espley, A. F., Potter, S. M., Ross, K. A., Tse, P., Bessen, N. P., Felmy, H. M., Lackey, H. E., Allred, J. R., Seiner, B. N., Lumetta, G. J., Nelson, G. L., Bryan, S. A., & Lines, A. M. (2025). Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement. ACS Omega. https://doi.org/10.1021/acsomega.4c07963

Vancouver

Serrano T, Espley AF, Potter SM, Ross KA, Tse P, Bessen NP, et al. Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement. ACS Omega. 2025. doi:10.1021/acsomega.4c07963

BibTeX
@article{Serrano2025,
  author = {Serrano, Thomas and Espley, Alyssa F and Potter, Savannah M and Ross, Kenneth A and Tse, PoKi and Bessen, Nathan P and Felmy, Heather M and Lackey, Hope E and Allred, Jarrod R and Seiner, Brienne N and Lumetta, Gregg J and Nelson, Gilbert L and Bryan, Samuel A and Lines, Amanda M},
  title = {Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement},
  journal = {ACS Omega},
  year = {2025},
  doi = {10.1021/acsomega.4c07963}
}
Kostenlos starten →