Fachartikel in der Zeitschrift ACS Omega, online erschienen am 10.10.2024. Verfasst von Lihua Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Energy and Power Engineering and Mechanical Engineering, North China Electric Power University, Beijing, 102206, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Government of Xinjiang Uygur Autonomous Region of China, China University of Petroleum, Beijing.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The pressure signal of the standpipe in the regeneration device for the catalytic cracking reaction is commonly used as a basis for equipment fault diagnosis. The device operates in environments of high temperature, strong vibration, and high flow rate. The standpipe pressure signal is easily interfered with by noise, making it difficult to extract pressure characteristics. In this study, a signal denoising algorithm based on pressure curve tortuosity and denoising intensity is proposed. A power spectrum threshold vector is utilized to filter the pressure in the circulating standpipe, and the denoising intensity and tortuosity after denoising are calculated. Taking the ratio of noise reduction intensity and tortuosity as the objective function, the noise reduction scheme of the pressure signal at different heights of the standpipe is determined. The denoised pressure signals are reconstructed, and the characteristic pressure signals of the circulating standpipe are extracted. The results indicate that the method suppressed the noise, enhanced the significance of characteristic parameters, and improved the accuracy of the fault diagnosis in the FCC units.

Autor:innen und Institutionen

  • Department of Energy and Power Engineering and Mechanical Engineering, North China Electric Power University, Beijing, 102206, China.
  • State Key Laboratory of Heavy Oil Processing, China University of Petroleum-Beijing at Karamay, Xinjiang, 834000, China.

ORCID-Profile: Lihua Huang

Förderung

  • Government of Xinjiang Uygur Autonomous Region of China
  • China University of Petroleum, Beijing

Zitieren

APA

Huang, L., Zhang, Z., Peng, W., Liu, J., Wan, J., Gao, G., & Wan, S. (2024). Research on Denoising Algorithm of Standpipe Pressure Signal in FCC Device Based on Tortuosity and Denoising Intensity. ACS Omega, 9(42), 43156-43164. https://doi.org/10.1021/acsomega.4c07233

Vancouver

Huang L, Zhang Z, Peng W, Liu J, Wan J, Gao G, et al. Research on Denoising Algorithm of Standpipe Pressure Signal in FCC Device Based on Tortuosity and Denoising Intensity. ACS Omega. 2024;9(42):43156-43164. doi:10.1021/acsomega.4c07233

BibTeX
@article{Huang2024,
  author = {Huang, Lihua and Zhang, Zitong and Peng, Wei and Liu, Jianxin and Wan, Jiangyun and Gao, Guogang and Wan, Shuting},
  title = {Research on Denoising Algorithm of Standpipe Pressure Signal in FCC Device Based on Tortuosity and Denoising Intensity},
  journal = {ACS Omega},
  year = {2024},
  volume = {9},
  number = {42},
  pages = {43156--43164},
  doi = {10.1021/acsomega.4c07233}
}
Kostenlos starten →