EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications

Md Sanwar Hossain iD, Narayanasamy Padmanathan, Md Mizanur R Badal iD, Kafil M Razeeb iD, Mamun Jamal iD

ACS Omega · 12.09.2024

DOI: 10.1021/acsomega.4c06090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 12.09.2024. Verfasst von Md Sanwar Hossain und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 67 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Ministry of Science and Technology, Government of the People?s Republic of Bangladesh.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study introduces a potentiometric pH sensor that is extremely sensitive and specifically designed for food and pharmaceutical applications. The sensor utilizes a pH-sensitive interface fabricated by electropolymerizing polyaniline (PANI) on carbon fiber cloth (CFC). Structural and morphological analyses of PANI-CFC and CFC have been conducted by using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and X-ray photoelectron spectroscopy (XPS). The investigation of the functional groups was conducted by using Fourier transform infrared spectroscopy (FTIR) and Raman spectroscopy. The electrochemical characteristics were assessed by utilization of cyclic voltammetry (CV) and open-circuit potential (OCP) measurements in a three-electrode configuration. The sensor exhibited a sensitivity of 60.9 mV/pH, while retaining consistent performance within the pH range of 4 to 12. The repeatability and robustness of the sensors were verified. The accuracy of the PANI-CFC sensor was confirmed by validation using real samples, demonstrating its compatibility with commercially available pH sensors. The application of density functional theory (DFT) calculations revealed an interaction energy of -173.2886 kcal/mol, indicating a strong affinity of H+ ions towards PANI-CFC electrode. Further investigation was conducted to examine the chemical reactivity of PANI, revealing a HOMO-LUMO energy gap of -0.98 eV. This study highlights the PANI-CFC sensor as a reliable and efficient pH-sensing platform for food and pharmaceuticals applications, performing robustly in both laboratory and real-world settings.

Autor:innen und Institutionen

  • Department of Chemistry, Khulna University of Engineering & Technology, Khulna 9203, Bangladesh.
  • Micro-NanoSystems Centre, Tyndall National Institute, University College Cork, Dyke Parade, Lee Maltings, Cork T12 R5CP, Ireland.

ORCID-Profile: Md Sanwar Hossain, Md Mizanur R Badal, Kafil M Razeeb, Mamun Jamal

Förderung

  • Ministry of Science and Technology, Government of the People?s Republic of Bangladesh

Zitieren

APA

Hossain, M. S., Padmanathan, N., Badal, M. M. R., Razeeb, K. M., & Jamal, M. (2024). Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications. ACS Omega. https://doi.org/10.1021/acsomega.4c06090

Vancouver

Hossain MS, Padmanathan N, Badal MMR, Razeeb KM, Jamal M. Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications. ACS Omega. 2024. doi:10.1021/acsomega.4c06090

BibTeX
@article{Hossain2024,
  author = {Hossain, Md Sanwar and Padmanathan, Narayanasamy and Badal, Md Mizanur R and Razeeb, Kafil M and Jamal, Mamun},
  title = {Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications},
  journal = {ACS Omega},
  year = {2024},
  doi = {10.1021/acsomega.4c06090}
}
Kostenlos starten →