Improper Background Treatment Underestimates Thermometric Performance of Rare Earth Vanadate and Phosphovanadate Nanocrystals
ACS Omega · 13.08.2024 · 9 (32) · 34974-34980
DOI: 10.1021/acsomega.4c04835 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Omega, online erschienen am 01.08.2024. Verfasst von Rafael Vieira Perrella und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Inorganic Chemistry, Institute of Chemistry, Universidade Estadual de Campinas (Unicamp), R. Monteiro Lobato, 270, Campinas, São Paulo …. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundo de Apoio ao Ensino, ? Pesquisa e Extens?o, Universidade Estadual de Campinas, Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico, Funda??o de Amparo ? Pesquisa do Estado de S?o Paulo.
Abstract (Originalsprache)
Luminescence thermometry is the state-of-the-art technique for remote nanoscale temperature sensing, offering numerous promising cutting-edge applications. Advancing nanothermometry further requires rational design of phosphors and well-defined, comprehensive mathematical treatment of spectral information. However, important questions regarding improper signal processing in ratiometric luminescence thermometry are continuously overlooked in the literature. Here, we demonstrate that systematic errors arising from background/signal superposition impact the calculated thermometric quality parameters of ratiometric thermometers. We designed ultraviolet-excitable (Y,Eu)VO4 and (Y,Eu)(P,V)O4 nanocrystals showing overlapped VO4 3- and Eu3+ emissions to discuss systematically how uncorrected background emissions cause magnified (∼10×) temperature uncertainties and undervalued (∼60%) relative thermal sensitivities. Adequate separation of spectral contributions from the VO4 3- background and the Eu3+ signals via baseline correction is necessary to prevent underestimation of the thermometric performances. The described approach can be potentially extended to other luminescent thermometers to account for signal superposition, thus enabling to circumvent computation of apparent, miscalculated thermometric parameters.
Autor:innen und Institutionen
- Department of Inorganic Chemistry, Institute of Chemistry, Universidade Estadual de Campinas (Unicamp), R. Monteiro Lobato, 270, Campinas, São Paulo 13083-970, Brazil.
ORCID-Profile: Rafael Vieira Perrella, Paulo Cesar de Sousa Filho
Förderung
- Fundo de Apoio ao Ensino, ? Pesquisa e Extens?o, Universidade Estadual de Campinas
- Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico
- Funda??o de Amparo ? Pesquisa do Estado de S?o Paulo
- Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior
Zitieren
APA
Vieira Perrella, R., Derroso, G., & de Sousa Filho, P. C. (2024). Improper Background Treatment Underestimates Thermometric Performance of Rare Earth Vanadate and Phosphovanadate Nanocrystals. ACS Omega, 9(32), 34974-34980. https://doi.org/10.1021/acsomega.4c04835
Vancouver
Vieira Perrella R, Derroso G, de Sousa Filho PC. Improper Background Treatment Underestimates Thermometric Performance of Rare Earth Vanadate and Phosphovanadate Nanocrystals. ACS Omega. 2024;9(32):34974-34980. doi:10.1021/acsomega.4c04835
BibTeX
@article{VieiraPerrella2024,
author = {Vieira Perrella, Rafael and Derroso, Gustavo and de Sousa Filho, Paulo Cesar},
title = {Improper Background Treatment Underestimates Thermometric Performance of Rare Earth Vanadate and Phosphovanadate Nanocrystals},
journal = {ACS Omega},
year = {2024},
volume = {9},
number = {32},
pages = {34974--34980},
doi = {10.1021/acsomega.4c04835}
}
EUVIMED