EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Plasmon-Enhanced Refractive Index Sensing of Biomolecules Based on Metal–Dielectric–Metal Metasurface in the Infrared Regime

Ghulam Abbas Khan iD, Yonghua Lu iD, Pei Wang

ACS Omega · 09.01.2024 · 9 (1) · 1416-1423

DOI: 10.1021/acsomega.3c07809 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Omega, online erschienen am 29.12.2023. Verfasst von Ghulam Abbas Khan und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optics and Optical Engineering, University of Science and Technology of China, Hefei 230026, China. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Natural Science Foundation of China, CAS-TWAS President Fellowship.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Infrared plasmonic sensors offer enhanced biomolecule detection potential over visible sensors due to unique spectral fingerprints, enhanced sensitivity, lower interference, and label-free, nondestructive analysis capabilities. Moreover, multimode plasmonic sensors are highly advantageous for their ability to outperform single-mode counterparts through long-wavelength tuning, enhanced information retrieval, and reduced false results through multimode data cross-referencing. In this study, to achieve a high quality factor and enhanced sensitivity simultaneously, we employed silver square block arrays (SSBs) in a metal-dielectric-metal configuration. The proposed design supports three modes resulting from gap plasmons and propagating surface plasmon resonances, enabling the detection of a broad spectrum of biomolecules. Designed sensors demonstrate notable sensitivities in different modes: Mode I achieves 525 nm/RIU, Mode II reaches 1287 nm/RIU, and Mode III records 812 nm/RIU, while maintaining the quality factor of Mode I-17, Mode II-356, and Mode III-107. The figure of merit for Mode I is 7 RIU-1, for Mode II it is 375 RIU-1, and for Mode III it is 98 RIU-1. Different concentrations of glucose and hemoglobin are efficiently detected with the proposed sensor, showing great potential for its biosensing application and real-time monitoring of biomolecule dynamics. Taken together, the proposed sensor exhibits the capability to identify diverse types of biomolecules and holds the potential to serve as a preliminary screening tool for various biomolecules.

Autor:innen und Institutionen

  • Department of Optics and Optical Engineering, University of Science and Technology of China, Hefei 230026, China.

ORCID-Profile: Ghulam Abbas Khan, Yonghua Lu

Förderung

  • National Natural Science Foundation of China
  • CAS-TWAS President Fellowship

Zitieren

APA

Khan, G. A., Lu, Y., & Wang, P. (2024). Plasmon-Enhanced Refractive Index Sensing of Biomolecules Based on Metal–Dielectric–Metal Metasurface in the Infrared Regime. ACS Omega, 9(1), 1416-1423. https://doi.org/10.1021/acsomega.3c07809

Vancouver

Khan GA, Lu Y, Wang P. Plasmon-Enhanced Refractive Index Sensing of Biomolecules Based on Metal–Dielectric–Metal Metasurface in the Infrared Regime. ACS Omega. 2024;9(1):1416-1423. doi:10.1021/acsomega.3c07809

BibTeX
@article{Khan2024,
  author = {Khan, Ghulam Abbas and Lu, Yonghua and Wang, Pei},
  title = {Plasmon-Enhanced Refractive Index Sensing of Biomolecules Based on Metal–Dielectric–Metal Metasurface in the Infrared Regime},
  journal = {ACS Omega},
  year = {2024},
  volume = {9},
  number = {1},
  pages = {1416--1423},
  doi = {10.1021/acsomega.3c07809}
}
Kostenlos starten →