High-Throughput SWCNT NIR-II Spectroscopy Enables Cell and In Vivo Applications
ACS Nanoscience Au · 19.08.2026 · 6 (4) · 674-684
DOI: 10.1021/acsnanoscienceau.6c00053 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Nanoscience Au, online erschienen am 01.06.2026. Verfasst von Atara R Israel und 7 weiteren Autor:innen. Beteiligte Einrichtung: The City College of New York, Department of Biomedical Engineering, New York, New York 10031, United States. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NIGMS NIH HHS, NIMHD NIH HHS, Stony Brook University.
Abstract (Originalsprache)
Diagnostic sensor development and clinical translation lag, in part, due to a lack of rapid, high-throughput screening methodologies. Optimization of high-throughput sensor development and deployment will likely help in expediting tools toward the clinic. To address this issue, we optimized high-throughput screening parameters using a near-infrared (NIR-II) plate reader attached to an external probe for in vivo testing. We assessed spectroscopy parameters to improve the speed and precision in screening a single-walled carbon nanotube (SWCNT)-based optical sensor. To do so, we assessed the appropriate well-plate specifications, including laser power, excitation wavelength, exposure time, and focal height parameters for SWCNT-based optical sensor development. We also used the plate reader to screen fluorescent SWCNTs that were endocytosed by a macrophage cell line. We then performed NIR probe spectroscopy to assess SWCNTs embedded within a methylcellulose hydrogel. Finally, we used the NIR probe to measure the SWCNT center wavelength and intensity from live immunocompetent mice. We anticipate that this framework may be broadly applicable to the development of near-infrared nanosensors with the potential for more rapid clinical diagnostic translation.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- The City College of New York, Department of Biomedical Engineering, New York, New York 10031, United States.
- Department of Medicine, Division of Nephrology & Hypertension, Stony Brook University, Stony Brook, New York 11794, United States.
ORCID-Profile: Ryan M Williams
Förderung
- NIGMS NIH HHS
- NIMHD NIH HHS
- Stony Brook University
- National Institute of General Medical Sciences
Zitieren
APA
Israel, A. R., Cohen, Z., Rahman, N., Vasylaki, A., Ryan, A. K., Rahman, S., Ghosh, P., & Williams, R. M. (2026). High-Throughput SWCNT NIR-II Spectroscopy Enables Cell and In Vivo Applications. ACS Nanoscience Au, 6(4), 674-684. https://doi.org/10.1021/acsnanoscienceau.6c00053
Vancouver
Israel AR, Cohen Z, Rahman N, Vasylaki A, Ryan AK, Rahman S, et al. High-Throughput SWCNT NIR-II Spectroscopy Enables Cell and In Vivo Applications. ACS Nanoscience Au. 2026;6(4):674-684. doi:10.1021/acsnanoscienceau.6c00053
BibTeX
@article{Israel2026,
author = {Israel, Atara R and Cohen, Zachary and Rahman, Nazifa and Vasylaki, Anastasiia and Ryan, Amelia K and Rahman, Syeda and Ghosh, Pratyusha and Williams, Ryan M},
title = {High-Throughput SWCNT NIR-II Spectroscopy Enables Cell and In Vivo Applications},
journal = {ACS Nanoscience Au},
year = {2026},
volume = {6},
number = {4},
pages = {674--684},
doi = {10.1021/acsnanoscienceau.6c00053}
}
EUVIMED