Accurate Sizing of Nanoparticles Using a High-Throughput Charge Detection Mass Spectrometer without Energy Selection
ACS Nano · 25.04.2023 · 17 (8) · 7765-7774
DOI: 10.1021/acsnano.3c00539 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Nano, online erschienen am 07.04.2023. Verfasst von Conner C Harper und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of California, Berkeley, California 94720-1460, United States. Die Arbeit wurde bisher 38-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Arnold and Mabel Beckman Foundation, National Institute of General Medical Sciences.
Abstract (Originalsprache)
The sizes and shapes of nanoparticles play a critical role in their chemical and material properties. Common sizing methods based on light scattering or mobility lack individual particle specificity, and microscopy-based methods often require cumbersome sample preparation and image analysis. A promising alternative method for the rapid and accurate characterization of nanoparticle size is charge detection mass spectrometry (CDMS), an emerging technique that measures the masses of individual ions. A recently constructed CDMS instrument designed specifically for high acquisition speed, efficiency, and accuracy is described. This instrument does not rely on an ion energy filter or estimates of ion energy that have been previously required for mass determination, but instead uses direct, in situ measurements. A standardized sample of ∼100 nm diameter polystyrene nanoparticles and ∼50 nm polystyrene nanoparticles with amine-functionalized surfaces are characterized using CDMS and transmission electron microscopy (TEM). Individual nanoparticle masses measured by CDMS are transformed to diameters, and these size distributions are in close agreement with distributions measured by TEM. CDMS analysis also reveals dimerization of ∼100 nm nanoparticles in solution that cannot be determined by TEM due to the tendency of nanoparticles to agglomerate when dried onto a surface. Comparing the acquisition and analysis times of CDMS and TEM shows particle sizing rates up to ∼80× faster are possible using CDMS, even when samples ∼50× more dilute were used. The combination of both high-accuracy individual nanoparticle measurements and fast acquisition rates by CDMS represents an important advance in nanoparticle analysis capabilities.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemistry, University of California, Berkeley, California 94720-1460, United States.
- Ardara Technologies LP, Ardara, Pennsylvania 15615, United States.
ORCID-Profile: Jacob S Jordan, Evan R Williams
Förderung
- NIGMS NIH HHS
- Arnold and Mabel Beckman Foundation
- National Institute of General Medical Sciences
- Merck
Zitieren
APA
Harper, C. C., Miller, Z. M., McPartlan, M. S., Jordan, J. S., Pedder, R. E., & Williams, E. R. (2023). Accurate Sizing of Nanoparticles Using a High-Throughput Charge Detection Mass Spectrometer without Energy Selection. ACS Nano, 17(8), 7765-7774. https://doi.org/10.1021/acsnano.3c00539
Vancouver
Harper CC, Miller ZM, McPartlan MS, Jordan JS, Pedder RE, Williams ER. Accurate Sizing of Nanoparticles Using a High-Throughput Charge Detection Mass Spectrometer without Energy Selection. ACS Nano. 2023;17(8):7765-7774. doi:10.1021/acsnano.3c00539
BibTeX
@article{Harper2023,
author = {Harper, Conner C and Miller, Zachary M and McPartlan, Matthew S and Jordan, Jacob S and Pedder, Randall E and Williams, Evan R},
title = {Accurate Sizing of Nanoparticles Using a High-Throughput Charge Detection Mass Spectrometer without Energy Selection},
journal = {ACS Nano},
year = {2023},
volume = {17},
number = {8},
pages = {7765--7774},
doi = {10.1021/acsnano.3c00539}
}
EUVIMED