EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sample-Specific Signal-to-Noise Ratio in Benchtop and Handheld NIR Reflectance Spectroscopy

Krzysztof B. Beć, Justyna Grabska, Lisa Obwaller, Heinz W. Siesler, Christian W. Huck

ACS Measurement Science Au · 11.11.2026

DOI: 10.1021/acsmeasuresciau.6c00331 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Measurement Science Au, online erschienen am 11.11.2026. Verfasst von Krzysztof B. Beć und 4 weiteren Autor:innen. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Science Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The signal-to-noise ratio (S/N) is often reported as an instrument property determined under idealized reference conditions. In practical near-infrared (NIR) spectroscopy, however, this nominal value does not reliably represent the wavelength-resolved precision of spectra acquired from real, absorbing, and scattering samples in a given presentation and measurement geometry. This study evaluates wavelength-resolved “at sample” S/N (sample-specific S/N) in one benchtop and five handheld NIR spectrometers that represent distinct optical principles. Standard and complex liquids and solids were used to expose varying absorption, scattering, and presentation regimes. Replicate-based pointwise S/N profiles were complemented by three compact regional effect-size analyses: a reference-normalized precision ratio (RPR), matched presentation fold changes, and pairwise instrument ratios calculated only within exact shared spectral windows. In the 96 instrument−condition combinations, RPR ranged from 0.0115 to 8.44, showing that the precision of a real sample can be strongly derated relative to a measured reference state, while values above unity also reveal that a particular reference geometry need not represent the most favorable coupling condition. Presentation effects were wavelength-specific; for example, on the NIRFlex N-500, the use of a reflector increased regional S/N 51.3-fold in 10,000−7500 cm−1 but reduced it to 0.286-fold in 5500−4000 cm−1 for the liquid Sinupret sample. Moreover, 10 of 13 instrument pairs reversed the order over the tested conditions even after comparison was restricted to their shared spectral window. The nested replicate design further showed frequent sensitivity to position/block changes relative to fixed-position repeats, although the sequential design does not uniquely isolate spatial heterogeneity. Thus, practical NIR precision is a conditional property of the combined sample, spectral window, presentation, reference workflow, and acquisition protocol; wavelength-resolved sample-specific S/N therefore provides a more application-relevant description than a single nominal instrument value.

Förderung

  • Austrian Science Fund

Zitieren

APA

Beć, K. B., Grabska, J., Obwaller, L., Siesler, H. W., & Huck, C. W. (2026). Sample-Specific Signal-to-Noise Ratio in Benchtop and Handheld NIR Reflectance Spectroscopy. ACS Measurement Science Au. https://doi.org/10.1021/acsmeasuresciau.6c00331

Vancouver

Beć KB, Grabska J, Obwaller L, Siesler HW, Huck CW. Sample-Specific Signal-to-Noise Ratio in Benchtop and Handheld NIR Reflectance Spectroscopy. ACS Measurement Science Au. 2026. doi:10.1021/acsmeasuresciau.6c00331

BibTeX
@article{Bec2026,
  author = {Beć, Krzysztof B. and Grabska, Justyna and Obwaller, Lisa and Siesler, Heinz W. and Huck, Christian W.},
  title = {Sample-Specific Signal-to-Noise Ratio in Benchtop and Handheld NIR Reflectance Spectroscopy},
  journal = {ACS Measurement Science Au},
  year = {2026},
  doi = {10.1021/acsmeasuresciau.6c00331}
}
Kostenlos starten →