EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB

Ensiyeh Mirsadoughi, Sayantan Tripathy iD, Fatemeh Zare iD, Gerard L Cote iD, Samuel Mabbott iD

ACS Measurement Science Au · 19.08.2026 · 6 (4) · 972-982

DOI: 10.1021/acsmeasuresciau.6c00016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACS Measurement Science Au, online erschienen am 01.07.2026. Verfasst von Ensiyeh Mirsadoughi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Texas A&M University, 101 Bizzell Street, College Station, Texas 77843, United States. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: United States-Ireland-Northern Ireland R&D Partnership, National Science Foundation (NSF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Creatine kinase-myocardial band (CK-MB) remains an important biomarker for the early diagnosis and clinical management of myocardial infarction. Here, we report a sensitive colorimetric assay for CK-MB based on a conformation-locked aptamer guanine-quadruplex (G-quadruplex) system integrated with magnetic nanoparticle capture and hyperbranched rolling circle amplification (HRCA). Target binding induces conformational unlocking of the aptamer, initiating HRCA-mediated signal amplification and generating a concentration-dependent colorimetric response in the presence of a chromogenic substrate. A compact 3D-printed imaging module, combined with a Python-based processing pipeline, was used to extract grayscale intensity values from assay images for quantitative analysis. Using only 25 μL of sample, the assay achieved limits of detection (LOD) of 0.268 ng/mL in aqueous samples and 0.328 ng/mL in blood-spiked samples, and limits of quantification (LOQ) of 0.89 ng/mL and 1.09 ng/mL, respectively, with a linear dynamic range of 0.5–100 ng/mL. Grayscale intensity was inversely proportional to CK-MB concentration, enabling quantitative detection across clinically relevant levels. The HRCA amplification process and target-induced activation were further validated by TapeStation gel electrophoresis, confirming the formation of amplified DNA nanostructures. This platform provides a low-volume, amplification-based strategy for CK-MB detection that is compatible with simple optical readout and has strong potential for point-of-care applications.

Schlagwörter

Stichwörter der Autor:innen

CK-MBHRCAaptamercolorimetricmyocardial infarction

Autor:innen und Institutionen

  • Department of Biomedical Engineering, Texas A&M University, 101 Bizzell Street, College Station, Texas 77843, United States.
  • Center for Remote Health Technologies & Systems, Texas A&M Engineering Experiment Station, 600 Discovery Drive, College Station, Texas 77840-3006, United States.
  • Department of Electrical and Computer Engineering, Texas A&M University, College Station, Texas 77840, United States.

ORCID-Profile: Sayantan Tripathy, Fatemeh Zare, Gerard L Cote, Samuel Mabbott

Förderung

  • United States-Ireland-Northern Ireland R&D Partnership
  • National Science Foundation (NSF)

Zitieren

APA

Mirsadoughi, E., Tripathy, S., Zare, F., Cote, G. L., & Mabbott, S. (2026). A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB. ACS Measurement Science Au, 6(4), 972-982. https://doi.org/10.1021/acsmeasuresciau.6c00016

Vancouver

Mirsadoughi E, Tripathy S, Zare F, Cote GL, Mabbott S. A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB. ACS Measurement Science Au. 2026;6(4):972-982. doi:10.1021/acsmeasuresciau.6c00016

BibTeX
@article{Mirsadoughi2026,
  author = {Mirsadoughi, Ensiyeh and Tripathy, Sayantan and Zare, Fatemeh and Cote, Gerard L and Mabbott, Samuel},
  title = {A Hyperbranched Rolling Circle Amplification Assay Using Aptamer–Hemin/G-Quadruplex Recognition for the Detection of Creatine Kinase-MB},
  journal = {ACS Measurement Science Au},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {972--982},
  doi = {10.1021/acsmeasuresciau.6c00016}
}
Kostenlos starten →