Challenges in PFAS Postdegradation Analysis: Insights from the PFAS-CTAB Model System
ACS Measurement Science Au · 19.02.2025 · 5 (1) · 135-144
DOI: 10.1021/acsmeasuresciau.4c00083 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Measurement Science Au, online erschienen am 22.01.2025. Verfasst von Chanaka Navarathna und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Utah, Salt Lake City, Utah 84112, United States. Die Arbeit wurde bisher 20-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Division of Chemistry, University of Utah, Alfred P. Sloan Foundation.
Abstract (Originalsprache)
Per- and polyfluoroalkyl substances (PFAS) are synthetic chemicals widely used for their oil and water-repellent properties. Their environmental persistence and potential health risks have raised significant concerns. As PFAS degrades through remediation or natural processes, they form complex mixtures of the original chemicals, transformation byproducts, and degradation additives. Analyzing PFAS after degradation presents analytical challenges due to possible chemical and physical interactions, including ion pairing, micelle formation, and complexation. These factors can significantly impact the precision and accuracy of PFAS measurements, yet they are often overlooked in PFAS degradation studies. In this work, we demonstrate that with the addition of ppb-level cetyltrimethylammonium bromide (CTAB), a cationic surfactant used in PFAS plasma-based degradation, the PFAS calibration curve linearity, sensitivity, and reproducibility are severely compromised. Isotopically labeled internal standards cannot fully correct these issues. Furthermore, the standard EPA methods 537.1, 533, and 1633 could not accurately recover PFAS concentrations in the PFAS and CTAB mixtures, with severe matrix effects observed for longer-chain and nitrogen-containing PFAS. Among these methods, Method 1633 is currently the most suitable option for postdegradation analysis. Method 1633 showed the lowest CTAB interference because this method used another weak ion pair additive, formic acid or acetic acid (in commercial lab analysis), to acidify the sample before LC-MS/MS analysis and added an isotopically labeled internal standard. For future PFAS degradation studies, we recommend systematically evaluating the matrix effect on the PFAS quantification using a recovery matrix to validate the analytical methods before use.
Autor:innen und Institutionen
- Department of Chemistry, University of Utah, Salt Lake City, Utah 84112, United States.
- Department of Chemistry, Wayne State University, Detroit, Michigan 48202, United States.
ORCID-Profile: Long Luo
Förderung
- Division of Chemistry
- University of Utah
- Alfred P. Sloan Foundation
- Environmental Laboratory
Zitieren
APA
Navarathna, C., Boateng, R. A., & Luo, L. (2025). Challenges in PFAS Postdegradation Analysis: Insights from the PFAS-CTAB Model System. ACS Measurement Science Au, 5(1), 135-144. https://doi.org/10.1021/acsmeasuresciau.4c00083
Vancouver
Navarathna C, Boateng RA, Luo L. Challenges in PFAS Postdegradation Analysis: Insights from the PFAS-CTAB Model System. ACS Measurement Science Au. 2025;5(1):135-144. doi:10.1021/acsmeasuresciau.4c00083
BibTeX
@article{Navarathna2025,
author = {Navarathna, Chanaka and Boateng, Ransford Appianin and Luo, Long},
title = {Challenges in PFAS Postdegradation Analysis: Insights from the PFAS-CTAB Model System},
journal = {ACS Measurement Science Au},
year = {2025},
volume = {5},
number = {1},
pages = {135--144},
doi = {10.1021/acsmeasuresciau.4c00083}
}
EUVIMED