Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling
ACS Measurement Science Au · 21.02.2024 · 4 (1) · 127-135
DOI: 10.1021/acsmeasuresciau.3c00049 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Measurement Science Au, online erschienen am 05.12.2023. Verfasst von Nipunika H Godage und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, Ohio 43606, United States. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: University of Toledo.
Abstract (Originalsprache)
This study addresses the challenges of matrix effects and interspecies plasma protein binding (PPB) on measurement variability during method validation across diverse plasma types (human, rat, rabbit, and bovine). Accurate measurements of small molecules in plasma samples often require matrix-matched calibration approaches with the use of specific plasma types, which may have limited availability or affordability. To mitigate the costs associated with human plasma measurements, we explore in this work the potential of cross-matrix-matched calibration using Bayesian hierarchical modeling (BHM) to correct for matrix effects associated with PPB. We initially developed a targeted quantitative approach utilizing biocompatible solid-phase microextraction coupled with liquid chromatography-mass spectrometry for xenobiotic analysis in plasma. The method was evaluated for absolute matrix effects across human, bovine, rat, and rabbit plasma comparing pre- and postmatrix extraction standards. Absolute matrix effects from 96 to 108% for most analytes across plasma sources indicate that the biocompatibility of the extraction phase minimizes interference coextraction. However, the extent of PPB in different media can still affect the accuracy of the measurement when the extraction of small molecules is carried out via free concentration, as in the case of microextraction techniques. In fact, while matrix-matched calibration revealed high accuracy, cross-matrix calibration (e.g., using a calibration curve generated from bovine plasma) proved inadequate for precise measurements in human plasma. A BHM was used to calculate correction factors for each analyte within each plasma type, successfully mitigating the measurement bias resulting from diverse calibration curve types used to quantify human plasma samples. This work contributes to the development of cost-effective, efficient calibration strategies for biofluids. Leveraging easily accessible plasma sources, like bovine plasma, for method optimization and validation prior to analyzing costly plasma (e.g., human plasma) holds substantial advantages applicable to biomonitoring and pharmacokinetic studies.
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, College of Natural Sciences and Mathematics, The University of Toledo, Toledo, Ohio 43606, United States.
- School of Green Chemistry and Engineering, The University of Toledo, Toledo, Ohio 43606, United States.
- Dr. Nina McClelland Laboratory for Water Chemistry and Environmental Analysis, The University of Toledo, Toledo, Ohio 43606, United States.
- Department of Environmental Sciences, The University of Toledo, Toledo, Ohio 43606, United States.
- PerkinElmer Inc., Woodbridge, Ontario L4L 8H1, Canada.
ORCID-Profile: Song S Qian, Emanuela Gionfriddo
Förderung
- University of Toledo
Zitieren
APA
Godage, N. H., Qian, S. S., Cudjoe, E., & Gionfriddo, E. (2024). Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling. ACS Measurement Science Au, 4(1), 127-135. https://doi.org/10.1021/acsmeasuresciau.3c00049
Vancouver
Godage NH, Qian SS, Cudjoe E, Gionfriddo E. Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling. ACS Measurement Science Au. 2024;4(1):127-135. doi:10.1021/acsmeasuresciau.3c00049
BibTeX
@article{Godage2024,
author = {Godage, Nipunika H and Qian, Song S and Cudjoe, Erasmus and Gionfriddo, Emanuela},
title = {Enhancing Quantitative Analysis of Xenobiotics in Blood Plasma through Cross-Matrix Calibration and Bayesian Hierarchical Modeling},
journal = {ACS Measurement Science Au},
year = {2024},
volume = {4},
number = {1},
pages = {127--135},
doi = {10.1021/acsmeasuresciau.3c00049}
}
EUVIMED